Inspection [09/2014 - ]: Procedure
- INSPECT SHIFT SOLENOID VALVE (SL1)
*a Component without harness connected
(Shift Solenoid Valve (SL1))- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition 1 - 2 20°C (68°F) 5.0 to 5.6 Ω - Connect a positive (+) lead with a 21 W bulb from the battery to terminal 2 and a negative (-) lead to terminal 1 of the shift solenoid valve (SL1) connector and check the operation of the valve.
OK
The valve moves and makes an operating sound.
If the result is not as specified, replace the shift solenoid valve (SL1).
- Measure the resistance according to the value(s) in the table below.
- INSPECT SHIFT SOLENOID VALVE (SL2)
HINT:
Use the same procedure as for the shift solenoid valve (SL1).
- INSPECT SHIFT SOLENOID VALVE (SL3)
HINT:
Use the same procedure as for the shift solenoid valve (SL1).
- INSPECT SHIFT SOLENOID VALVE (SL4)
HINT:
Use the same procedure as for the shift solenoid valve (SL1).
- INSPECT SHIFT SOLENOID VALVE (SL5)
HINT:
Use the same procedure as for the shift solenoid valve (SL1).
- INSPECT SHIFT SOLENOID VALVE (SLU)
HINT:
Use the same procedure as for the shift solenoid valve (SL1).
- INSPECT SHIFT SOLENOID VALVE (SLT)
HINT:
Use the same procedure as for the shift solenoid valve (SL1).
- INSPECT SHIFT SOLENOID VALVE (SL)
- Measure the resistance according to the value(s) in the table below.
*a Component without harness connected
(Shift Solenoid Valve (SL))Standard Resistance
Tester Connection Condition Specified Condition Shift solenoid valve (SL) connector terminal - Shift solenoid valve (SL) body 20°C (68°F) 11 to 15 Ω - Connect a positive (+) lead from the battery to the terminal of the shift solenoid valve (SL) connector, and a negative (-) lead to the shift solenoid valve (SL) body, and check the operation of the valve.
OK
The valve moves and makes an operating sound.
If the result is not as specified, replace the shift solenoid valve (SL).
- Measure the resistance according to the value(s) in the table below.
- INSPECT SHIFT SOLENOID VALVE (SR)
- Measure the resistance according to the value(s) in the table below.
*a Component without harness connected
(Shift Solenoid Valve (SR))Standard Resistance
Tester Connection Condition Specified Condition Shift solenoid valve (SR) connector terminal - Shift solenoid valve (SR) body 20°C (68°F) 11 to 15 Ω - Connect a positive (+) lead from the battery to the terminal of the shift solenoid valve (SR) connector, and a negative (-) lead to the shift solenoid valve (SR) body, and check the operation of the valve.
OK
The valve moves and makes an operating sound.
If the result is not as specified, replace the shift solenoid valve (SR).
- Measure the resistance according to the value(s) in the table below.