Inspection [09/2015 - ]: Procedure
- INSPECT LIGHT CONTROL RHEOSTAT (TRIP SWITCH)
Check the resistance.
Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Switch Condition Specified Condition 4 (A/B) - 1 (E) ODO TRIP switch on (Pushed) Below 1 Ω ODO TRIP switch off (Not pushed) 10 kΩ or higher If the result is not as specified, replace the light control rheostat (trip switch).
TEXT IN ILLUSTRATION* a ODO TRIP Switch * b Component without harness connected
(Light Control Rheostat (Trip Switch))Check the illumination.
Apply battery voltage to the connector and check the illumination condition.
OK
Measurement Condition Specified Condition Battery positive (+) → Terminal 2 (ILL+)
Battery negative (-) → Terminal 3 (ILL-)Illuminates If the result is not as specified, replace the light control rheostat (trip switch).
TEXT IN ILLUSTRATION* a Component without harness connected
(Light Control Rheostat (Trip Switch))