Removal [09/2015 - ]: Procedure
- RECOVER REFRIGERANT FROM REFRIGERATION SYSTEM
See step 1
- REMOVE COWL TOP VENTILATOR LOUVER RH
Refer to PROCEDURE - Step 2
- PRECAUTION NOTE:
After turning the engine switch off, waiting time may be required before disconnecting the cable from the battery terminal. Therefore, make sure to read the disconnecting the cable from the battery terminal notice before proceeding with work (Refer to PRECAUTION [09/2015 - ] ).
- DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL NOTE:
When disconnecting the cable, some systems need to be initialized after the cable is reconnected (Refer to INITIALIZATION [09/2015 - ] ).
- REMOVE EXHAUST MANIFOLD SUB-ASSEMBLY LH
(Refer to REMOVAL [09/2015 - ] )
- DISCONNECT SUCTION TUBE SUB-ASSEMBLY B
- Remove the bolt and disconnect the suction tube sub-assembly B from the with pulley compressor assembly.
- Remove the O-ring from the cooler refrigerant suction tube sub-assembly B.NOTE:
Seal the openings of the disconnected parts using vinyl tape to prevent moisture and foreign matter from entering them.
- Remove the bolt and disconnect the suction tube sub-assembly B from the with pulley compressor assembly.
- DISCONNECT DISCHARGE HOSE SUB-ASSEMBLY
- REMOVE WITH PULLEY COMPRESSOR ASSEMBLY