LEMON Manuals: Even more car manuals for everyone
Home >> Lexus >> 2017 >> IS 350 Base, AWD >> Repair and Diagnosis >> Accessories & Equipment >> Gauges & Instrument Panels >> Meter / Gauge System - Symptom Tests (2 Of 2) & Circuit Tests >> Meter / Gauge System >> Engine Oil Level Sensor Circuit [09/2020 - 11/2021] >> Procedure

Engine Oil Level Sensor Circuit [09/2020 - 11/2021]: Procedure

  1. READ VALUE USING TECHSTREAM 
    1. Connect the Techstream to the DLC3.
    2. Turn the engine switch on (IG).
    3. Turn the Techstream on.
    4. Enter the following menus: Body Electrical / Combination Meter / Data List.
    5. Read the Data List according to the display on the Techstream.

      Body Electrical > Combination Meter > Data List 

      Tester Display Measurement Item Range Normal Condition Diagnostic Note
      Oil Level SW Engine oil level sensor OFF or ON OFF: Engine oil level not low
      ON: Engine oil level low
      -

      Body Electrical > Combination Meter > Data List 

      Tester Display
      Oil Level SW

      Result

      Result Proceed to
      The Data List item changes correctly A
      The Data List item do not change correctly B

    Result: 

    REPLACE COMBINATION METER ASSEMBLY. Refer to  REMOVAL [09/2020 - ] 

    Result: 

    See step  2

  2. INSPECT ENGINE OIL LEVEL SENSOR 
    1. Remove the engine oil level sensor.

      for 8AR-FTS: Refer to REMOVAL [10/2016 - ]

      for 2GR-FKS: Refer to REMOVAL [10/2017 - ]

    2. Inspect the engine oil level sensor.

      for 8AR-FTS: Refer to INSPECTION [08/2015 - ]

      for 2GR-FKS: Refer to INSPECTION [10/2017 - ]

      Result

      Proceed to
      OK
      NG

    Result: 

    NG 

    REPLACE ENGINE OIL LEVEL SENSOR 

    for 8AR-FTS: Refer to REMOVAL [10/2016 - ]

    for 2GR-FKS: Refer to REMOVAL [10/2017 - ]

    Result: 

    OK 

    See step  3

  3. CHECK HARNESS AND CONNECTOR (ENGINE OIL LEVEL SENSOR - COMBINATION METER ASSEMBLY) 
    1. Disconnect the K3 combination meter assembly connector.
    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance (for 8AR-FTS)

      Tester Connection Condition Specified Condition
      F64-1 (LOIL) - K3-15 (OILW) Always Below 1 Ω
      F64-1 (LOIL) or K3-15 (OILW) - Body ground Always 10 kΩ or higher
      F64-2 (GND) - Body ground Always Below 1 Ω

      Standard Resistance (for 2GR-FKS)

      Tester Connection Condition Specified Condition
      F117-1 (LOIL) - K3-15 (OILW) Always Below 1 Ω
      F117-1 (LOIL) or K3-15 (OILW) - Body ground Always 10 kΩ or higher

      Result

      Proceed to
      OK
      NG

    Result: 

    OK 

    REPLACE COMBINATION METER ASSEMBLY. Refer to  REMOVAL [09/2020 - ] 

    Result: 

    NG 

    REPAIR OR REPLACE HARNESS OR CONNECTOR