Inspection [04/2013 - ]: Procedure
- INSPECT SHIFT SOLENOID VALVE SL1
*a Component without harness connected
(Shift Solenoid Valve SL1)- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition 1 - 2 20°C (68°F) 5.0 to 5.6 Ω - Connect the positive (+) lead with a 21 W bulb to terminal 2 and the negative (-) lead to terminal 1 of the shift solenoid valve SL1 connector, then check the movement of the valve.
OK
The solenoid makes an operating sound.
If the result is not as specified, replace the shift solenoid valve SL1.
- Measure the resistance according to the value(s) in the table below.
- INSPECT SHIFT SOLENOID VALVE SL2
HINT:
Refer to the procedures for the shift solenoid valve SL1.
- INSPECT SHIFT SOLENOID VALVE SL3
HINT:
Refer to the procedures for the shift solenoid valve SL1.
- INSPECT SHIFT SOLENOID VALVE SL4
HINT:
Refer to the procedures for the shift solenoid valve SL1.
- INSPECT SHIFT SOLENOID VALVE SL5
HINT:
Refer to the procedures for the shift solenoid valve SL1.
- INSPECT SHIFT SOLENOID VALVE SLU
HINT:
Refer to the procedures for the shift solenoid valve SL1.
- INSPECT SHIFT SOLENOID VALVE SLT
HINT:
Refer to the procedures for the shift solenoid valve SL1.
- INSPECT SHIFT SOLENOID VALVE SL
- Measure the resistance according to the value(s) in the table below.
*a Component without harness connected
(Shift Solenoid Valve SL)Standard Resistance
Tester Connection Condition Specified Condition Shift solenoid valve SL connector terminal - Shift solenoid valve SL body 20°C (68°F) 11 to 15 Ω - Connect the positive (+) lead to the terminal of the shift solenoid valve SL connector, and the negative (-) lead to the shift solenoid valve SL body.
OK
The solenoid makes an operating sound
If the result is not as specified, replace the shift solenoid valve SL.
- Measure the resistance according to the value(s) in the table below.
- INSPECT SHIFT SOLENOID VALVE SR
- Measure the resistance according to the value(s) in the table below.
*a Component without harness connected
(Shift Solenoid Valve SR)Standard Resistance
Tester Connection Condition Specified Condition Shift solenoid valve SR connector terminal - Shift solenoid valve SR body 20°C (68°F) 11 to 15 Ω - Connect the positive (+) lead to the terminal of the shift solenoid valve SR connector, and the negative (-) lead to the shift solenoid valve SR body.
OK
The solenoid makes an operating sound
If the result is not as specified, replace the shift solenoid valve SR.
- Measure the resistance according to the value(s) in the table below.