Parking Brake Switch Circuit [04/2013 - 10/2016]: Procedure
- READ VALUE USING TECHSTREAM
- Connect the Techstream to the DLC3.
- Turn the engine switch on (IG).
- Turn the Techstream on.
- Enter the following menus: Body Electrical / Main Body / Data List.
- Read the display on the Techstream.
Body Electrical > Main Body > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note Parking Brake SW Parking brake switch signal ON or OFF ON: Parking brake switch on
OFF: Parking brake switch off- Body Electrical > Main Body > Data List
Tester Display Parking Brake SW OK
Normal conditions listed above are displayed.
Result
Proceed to OK NG
Result:
OK
PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE. Refer to PROBLEM SYMPTOMS TABLE [04/2013 - 06/2014] , or refer to PROBLEM SYMPTOMS TABLE [06/2014 - 08/2015] , or refer to PROBLEM SYMPTOMS TABLE [08/2015 - 10/2016]
Result:
NG
See step 2
- INSPECT PARKING BRAKE SWITCH ASSEMBLY
- Remove the parking brake switch assembly.
Refer to REMOVAL [04/2013 - 09/2020]
- Inspect the parking brake switch assembly.
Refer to INSPECTION [04/2013 - 09/2020]
Result
Proceed to OK NG
Result:
NG
REPLACE PARKING BRAKE SWITCH ASSEMBLY. Refer to REMOVAL [04/2013 - 09/2020]
Result:
OK
See step 3
- Remove the parking brake switch assembly.
- CHECK HARNESS AND CONNECTOR (PARKING BRAKE SWITCH ASSEMBLY - INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY)
- Disconnect the 4C instrument panel junction block assembly connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition A51-1 (+) - 4C-15 Always Below 1 Ω A51-1 (+) - Body ground Always 10 kΩ or higher Result
Proceed to OK NG
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
Result:
OK
See step 4
- INSPECT INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY
- Remove the instrument panel junction block assembly.
Refer to REMOVAL [04/2013 - ]
- Remove the main body ECU (multiplex network body ECU) from the instrument panel junction block assembly.
- Measure the resistance according to the value(s) in the table below.
*a Component without harness connected
(Instrument Panel Junction Block Assembly)- - Standard Resistance
Tester Connection Condition Specified Condition 4C-15 - MB-12 (PKB) Always Below 1 Ω 4C-15 - Body ground Always 10 kΩ or higher Result
Proceed to OK NG
Result:
OK
REPLACE MAIN BODY ECU (MULTIPLEX NETWORK BODY ECU). Refer to REMOVAL [04/2013 - ]
Result:
NG
REPLACE INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY. Refer to REMOVAL [04/2013 - ]
- Remove the instrument panel junction block assembly.