LEMON Manuals: Even more car manuals for everyone
Home >> Lexus >> 2017 >> IS 300 F Sport >> Repair and Diagnosis >> External Pages >> Different car >> Section 12 (Engine Intake / Exhaust System (4GR-FSE) - Service Information) >> INTAKE AIR CONTROL VALVE (for ACIS) >> On-Vehicle Inspection [04/2013 - 08/2015] >> Procedure

On-Vehicle Inspection [04/2013 - 08/2015]: Procedure

WARNING: This page is about a different car, the 2015 Lexus IS 250 and 2014 Lexus IS 250. However, it is still accessible from the selected car via links, so may be relevant.
  1. INSPECT INTAKE AIR CONTROL VALVE (for ACIS) 
    1. Perform the following inspection procedure when using the Techstream:
      1. Remove the V-bank cover sub-assembly.

        Refer to PROCEDURE - Step 3

      2. Stop the engine.
      3. Connect the Techstream to the DLC3.
      4. Start the engine and turn the Techstream on.
      5. Enter the following menus: Powertrain / Engine / Active Test / Activate the VSV for Intake Control.

        Powertrain > Engine > Active Test 

        Tester Display
        Activate the VSV for Intake Control
      6. Make sure that a clicking sound is heard from the intake air control valve (for ACIS) when current flows.

        If the intake air control valve (for ACIS) does not operate, check the ACIS control circuit.

        Refer to ACIS Control Circuit [04/2013 - 08/2015]

      7. Install the V-bank cover sub-assembly.

        Refer to PROCEDURE - Step 104

    2. Perform the following inspection procedure when not using the Techstream:
      1. Remove the V-bank cover sub-assembly.

        Refer to PROCEDURE - Step 3

      2. Disconnect the intake air control valve (for ACIS) connector.
      3. Apply battery voltage between terminals 1 (+) and 2 (-) of the intake air control valve (for ACIS). Check that a clicking sound is heard from the intake air control valve (for ACIS).

        If the result is not as specified, replace the intake air surge tank assembly.

        GTY443264Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
      4. Install the V-bank cover sub-assembly.

        Refer to PROCEDURE - Step 104