On-Vehicle Inspection [11/2021 - ]: Procedure
WARNING: This page is about a different car, the 2024 Lexus IS 500, 2023 Lexus IS 500, and 2022 Lexus IS 500. However, it is still accessible from the selected car via links, so may be relevant.
- INSPECT INJECTOR RELAY (INJ NO. 1)
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition 3 - 5 Battery voltage not applied between terminals 1 and 2 10 kΩ or higher Battery voltage applied between terminals 1 and 2 Below 1 Ω If the result is not as specified, replace the injector relay (INJ NO. 1).
- Measure the resistance according to the value(s) in the table below.
- INSPECT INJECTOR RELAY (INJ NO. 2)
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition 3 - 5 Battery voltage not applied between terminals 1 and 2 10 kΩ or higher Battery voltage applied between terminals 1 and 2 Below 1 Ω If the result is not as specified, replace the injector relay (INJ NO. 2).
- Measure the resistance according to the value(s) in the table below.
- INSPECT EFI CIRCUIT OPENING RELAY ASSEMBLY (C/OPN) (for Brush Type Motor)
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition 3 - 5 Battery voltage not applied between terminals 1 and 2 10 kΩ or higher Battery voltage applied between terminals 1 and 2 Below 1 Ω If the result is not as specified, replace the EFI circuit opening relay assembly (C/OPN).
- Measure the resistance according to the value(s) in the table below.
- INSPECT EFI 2 RELAY (EFI MAIN NO. 2)
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition 3 - 5 Battery voltage not applied between terminals 1 and 2 10 kΩ or higher Battery voltage applied between terminals 1 and 2 Below 1 Ω If the result is not as specified, replace the EFI 2 relay (EFI MAIN NO. 2).
- Measure the resistance according to the value(s) in the table below.
- INSPECT VVT RELAY (VVT NO. 1)
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition 3 - 5 Battery voltage not applied between terminals 1 and 2 10 kΩ or higher Battery voltage applied between terminals 1 and 2 Below 1 Ω If the result is not as specified, replace the VVT relay (VVT NO. 1).
- Measure the resistance according to the value(s) in the table below.
- INSPECT VVT RELAY (VVT NO. 2)
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition 3 - 5 Battery voltage not applied between terminals 1 and 2 10 kΩ or higher Battery voltage applied between terminals 1 and 2 Below 1 Ω If the result is not as specified, replace the VVT relay (VVT NO. 2).
- Measure the resistance according to the value(s) in the table below.