Home >> Lexus >> 2017 >> IS 300 F Sport >> Repair and Diagnosis >> External Pages >> Different car >> Section 105 (Automatic Transmission System (Aa80E) - Diagnostic Codes (2 Of 2) & Circuit Tests) >> Automatic Transmission System >> DTC P2808: Pressure Control Solenoid "G" Performance (Shift Solenoid Valve SL4) [11/2021 - ] >> Typical Malfunction Thresholds

Typical Malfunction Thresholds

WARNING: This page is about a different car, the 2024 Lexus IS 500, 2023 Lexus IS 500, and 2022 Lexus IS 500. However, it is still accessible from the selected car via links, so may be relevant.

OFF malfunction 

  1. When one of following conditions is met: OFF malfunction (A), (B), (C), (D) or (E)

    OFF malfunction (A) 

    1. When either condition below is met: Condition (1) or (2)
      CONDITION (1)

      Turbine speed / Output speed (NT / NO) 3.9 or more and 8.0 or less
      (when output speed less than 130 rpm)
      CONDITION (2)

      Turbine speed - Output speed (NT - NO) x 1st gear ratio
      (Actual 1st gear)
      -50 rpm or more and 50 rpm or less
      (when output speed 130 rpm or more)

    OFF malfunction (B) 

    1. Turbine speed - Output speed (NT - NO) x 4th gear ratio 400 rpm or more

    OFF malfunction (C) 

    1. Turbine speed - Output speed (NT - NO) x 6th gear ratio 400 rpm or more

    OFF malfunction (D) 

    1. Shift solenoid valve SLT ON malfunction

ON malfunction 

  1. When one of the following conditions is met: ON malfunction (A), (B), (C) or (D)

    2 detections are necessary per driving cycle:

    1st detection: temporary flag ON

    2nd detection: pending fault code ON

    ON malfunction (A) and (B) 

    1. When either condition below is met: Condition (1) or (2)
      CONDITION (1)

      Turbine speed / Output speed (NT / NO) 1.354 or more and 1.584 or less
      (when output speed less than 600 rpm)
      CONDITION (2)

      Turbine speed - Output speed (NT - NO) x 4th gear ratio
      (Actual 4th gear)
      -50 rpm or more and 50 rpm or less
      (when output speed 600 rpm or more)

    ON malfunction (C) and (D) 

    1. When either condition below is met: Condition (1) or (2)
      CONDITION (1)

      Turbine speed / Output speed (NT / NO) 0.93 or more and 1.07 or less
      (when output speed less than 800 rpm)
      CONDITION (2)

      Turbine speed - Output speed (NT - NO) x 6th gear ratio
      (Actual 6th gear)
      -50 rpm or more and 50 rpm or less
      (when output speed 800 rpm or more)