LEMON Manuals: Even more car manuals for everyone
Home >> Lexus >> 2017 >> IS 300 F Sport >> Repair and Diagnosis >> External Pages >> Different car >> Section 105 (Automatic Transmission System (Aa80E) - Diagnostic Codes (2 Of 2) & Circuit Tests) >> Automatic Transmission System >> DTC P0796: Pressure Control Solenoid "C" Performance (Shift Solenoid Valve SL3) [11/2021 - ] >> Typical Malfunction Thresholds

Typical Malfunction Thresholds

WARNING: This page is about a different car, the 2024 Lexus IS 500, 2023 Lexus IS 500, and 2022 Lexus IS 500. However, it is still accessible from the selected car via links, so may be relevant.

OFF malfunction 

  1. When one of the following conditions is met: OFF malfunction (A), (B), (C), (D) or (E)

    OFF malfunction (A) 

    1. When either condition below is met: Condition (1) or (2)
      CONDITION (1)

      Turbine speed / Output speed (NT / NO) 3.9 or more and 8.0 or less
      (when output speed less than 130 rpm)
      CONDITION (2)

      Turbine speed - Output speed (NT - NO) x 1st gear ratio
      (Actual 1st gear)
      -50 rpm or more and 50 rpm or less
      (when output speed 130 rpm or more)

    OFF malfunction (B) 

    1. Turbine speed - Output speed (NT - NO) x 3rd gear ratio 400 rpm or more

    OFF malfunction (C) 

    1. Turbine speed - Output speed (NT - NO) x 7th gear ratio 400 rpm or more

    OFF malfunction (D) 

    1. Shift solenoid valve SLT ON malfunction

ON malfunction 

  1. When one of following conditions is met: ON malfunction (A), (B), (C), (D), (E) or (F)

    2 detections are necessary per driving cycle:

    1st detection: temporary flag ON

    2nd detection: pending fault code ON

    ON malfunction (A), (B) and (C) 

    1. When either condition below is met: Condition (1) or (2)
      CONDITION (1)

      Turbine speed / Output speed (NT / NO) 1.72 or more and 2.07 or less
      (when output speed less than 400 rpm)
      CONDITION (2)

      Turbine speed - Output speed (NT - NO) x 3th gear ratio
      (Actual 3rd gear)
      -50 rpm or more and 50 rpm or less
      (when output speed 400 rpm or more)

    ON malfunction (D), (E) and (F) 

    1. When either condition below is met: Condition (1) or (2)
      CONDITION (1)

      Turbine speed / Output speed (NT / NO) 0.759 or more and 0.889 or less
      (when output speed less than 800 rpm)
      CONDITION (2)

      Turbine speed - Output speed (NT - NO) x 7rd gear ratio
      (Actual 7th gear)
      -50 rpm or more and 50 rpm or less
      (when output speed 800 rpm or more)