Operating Light Control Rheostat does not Change Light Brightness [08/2019 - ]: Procedure
- READ VALUE USING TECHSTREAM
- Using the Techstream, read the Data List.
Refer to DATA LIST / ACTIVE TEST [08/2019 - ]
BODY ELECTRICAL > COMBINATION METER > DATA LISTTester Display Measurement Item / Range Normal Condition Diagnostic Note Light Control Up Switch Light control rheostat up switch / OFF or ON OFF: Light control rheostat up switch not pressed
ON: Light control rheostat up switch pressed- Light Control Down Switch Light control rheostat down switch / OFF or ON OFF: Light control rheostat up switch not pressed
ON: Light control rheostat up switch pressed- OK
Light control rheostat condition displayed on the Techstream changes with the actual switch operation.
Result
Proceed to OK NG
Result:
OK
REPLACE COMBINATION METER ASSEMBLY. Refer to REMOVAL [08/2019 - ]
Result:
NG
See step 2
- Using the Techstream, read the Data List.
- INSPECT LIGHT CONTROL RHEOSTAT
- Remove the light control rheostat.
Refer to REMOVAL [08/2019 - ]
- Inspect the light control rheostat.
Refer to INSPECTION [08/2019 - ]
Result
Proceed to OK NG
Result:
NG
REPLACE LIGHT CONTROL RHEOSTAT. Refer to REMOVAL [08/2019 - ]
Result:
OK
See step 3
- Remove the light control rheostat.
- CHECK HARNESS AND CONNECTOR (LIGHT CONTROL RHEOSTAT - COMBINATION METER ASSEMBLY AND BODY GROUND)
- Disconnect the G3 combination meter assembly connector.
- Disconnect the G102 light control rheostat connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition G3-8 (RHUP) - G102-3 (UP) Always Below 1 Ω G3-13 (RHDW) - G102-2 (DOWN) Always Below 1 Ω G102-4 (E) - Body ground Always Below 1 Ω G3-8 (RHUP) or G102-3 (UP) - Body ground Always 10 kΩ or higher G3-13 (RHDW) or G102-2 (DOWN) - Body ground Always 10 kΩ or higher Result
Proceed to OK NG
Result:
OK
REPLACE COMBINATION METER ASSEMBLY. Refer to REMOVAL [08/2019 - ]
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR