Odo/Trip Switch Malfunction [08/2019 - ]: Procedure
- READ VALUE USING TECHSTREAM (ODO/TRIP CHANGE SW)
- Using the Techstream, read the Data List.
Refer to DATA LIST / ACTIVE TEST [08/2019 - ]
BODY ELECTRICAL > COMBINATION METER > DATA LISTTester Display Measurement Item / Range Normal Condition Diagnostic Note ODO/TRIP Change SW ODO/TRIP switch / OFF or ON OFF: Switch released
ON: Switch pushed- OK
The value displayed on the Techstream changes with the actual ODO/TRIP change switch operation.
Result
Proceed to OK NG
Result:
OK
REPLACE COMBINATION METER ASSEMBLY. Refer to REMOVAL [08/2019 - ]
Result:
NG
See step 2
- Using the Techstream, read the Data List.
- INSPECT COMBINATION SWITCH ASSEMBLY
- Remove the combination switch assembly.
Refer to REMOVAL [08/2019 - ]
- Inspect the combination switch assembly.
Refer to INSPECTION [08/2019 - ]
Result
Proceed to OK NG
Result:
NG
REPLACE COMBINATION SWITCH ASSEMBLY. Refer to REMOVAL [08/2019 - ]
Result:
OK
See step 3
- Remove the combination switch assembly.
- CHECK HARNESS AND CONNECTOR (COMBINATION SWITCH ASSEMBLY - COMBINATION METER ASSEMBLY AND BODY GROUND)
- Disconnect the G3 combination meter assembly connector.
- Disconnect the G123 combination switch assembly connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition G3-14 (RSET) - G123-1 (A/B) Always Below 1 Ω G123-3 (E) - Body ground Always Below 1 Ω G3-14 (RSET) or G123-1 (A/B) - Body ground Always 10 kΩ or higher Result
Proceed to OK NG
Result:
OK
REPLACE COMBINATION METER ASSEMBLY. Refer to REMOVAL [08/2019 - ]
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR