ODO/Trip Switch Malfunction [09/2014 - 10/2015]: Procedure
- READ VALUE USING TECHSTREAM (TRIP SWITCH)
- Use the Data List to check the trip switch (Refer to DATA LIST / ACTIVE TEST [09/2014 - 10/2015]
).COMBINATION METER
Tester Display Measurement Item/Range Normal Condition Diagnostic Note ODO/TRIP Change SW ODO/TRIP switch/OFF or ON OFF: ODO/TRIP switch released - ON: ODO/TRIP switch pushed OK
The value displayed on the Techstream changes in accordance with the actual ODO/TRIP switch operation.
Result: OK
OK
REPLACE COMBINATION METER ASSEMBLY
(Refer to REMOVAL [09/2014 - ] )
Result: NG
NG
See step 2
- Use the Data List to check the trip switch (Refer to DATA LIST / ACTIVE TEST [09/2014 - 10/2015]
).
- INSPECT TRIP SWITCH
- Remove the trip switch (Refer to REMOVAL [09/2014 - ] ).
- Inspect the trip switch (Refer to INSPECTION [09/2014 - ] ).
Result: NG
NG
REPLACE TRIP SWITCH
(Refer to REMOVAL [09/2014 - ] )
Result: OK
OK
See step 3
- CHECK HARNESS AND CONNECTOR (COMBINATION METER ASSEMBLY - TRIP SWITCH AND BODY GROUND)
- Disconnect the N40 combination meter assembly connector.
- Disconnect the N8 trip switch connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition N40-37 (RSET) - N8-2 (A/B) Always Below 1 Ω N8-5 (E) - Body ground N40-37 (RSET) - Body ground Always 10 kΩ or higher
Result: OK
OK
REPLACE COMBINATION METER ASSEMBLY
(Refer to REMOVAL [09/2014 - ] )
Result: NG
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR