Customize Parameters [09/2014 - 10/2015]: Procedure
- CUSTOMIZE METER / GAUGE SYSTEM
- Customizing with the Techstream
- Connect the Techstream to the DLC3.
- Turn the engine switch on (IG).
- Turn the Techstream on.
- Enter the following menus: Customize Setting / Combination Meter / Warning or Display.
- Select the setting by referring to the table below.WARNING
Display Default Content Setting Relevant ECU Driver Side Seatbelt Warning Buzzer* ON Function to turn on/off the seat belt warning buzzer ON or OFF Combination meter assembly Front Passenger Side Seatbelt Warning Buzzer* ON Function to turn on/off the seat belt warning buzzer ON or OFF Combination meter assembly Flasher Sound Volume Adjustment Large Function to change the flasher sound volume Large, Medium or Small Combination meter assembly - *: This setting is only valid for the buzzer which sounds at 20 km/h (12 mph) or more
DISPLAYDisplay Default Content Setting Relevant ECU ECO Drive Indicator Zone ON Function to enable or disable eco driving indicator zone display in the multi-information display ON or OFF Combination meter assembly ODO Display Time After IG OFF Setting 30 s Function to change the odometer display time 30 s, 60 s, 600 s or OFF Combination meter assembly
- Customizing with the combination meter assembly
- Turn the engine switch on (IG).
- Enter the following menus: Settings.
- Select the setting by referring to the table below.METER SETTING
Display Default Content Setting Relevant ECU Language English Function to change the multi-information display language English, Francais or Espanol Combination meter assembly Units miles (MPG) Function to change the multi-information display unit km (km/L), km (L/100km) or miles (MPG) Combination meter assembly ECO Indicator ON Function to turn on/off the eco light ON or OFF Combination meter assembly Drive monitor OUTSIDE Function to change the drive monitor setting AVERAGE, CRUISING RANGE or OUTSIDE Combination meter assembly DEFAULT SETTINGS OFF Function to turn on/off the default setting ON or OFF Combination meter assembly
- Customizing with the Techstream