Inspection [09/2014 - ]: Procedure
- INSPECT TRIP SWITCH (LIGHT CONTROL RHEOSTAT)
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Switch Condition Specified Condition 3 (IG) - 5 (E) Up switch on
(Pushed)Below 1 Ω 3 (IG) - 5 (E) Up switch off
(Not pushed)10 kΩ or higher 3 (IG) - 5 (E) Down switch on
(Pushed)1.7 to 1.8 kΩ 3 (IG) - 5 (E) Down switch off
(Not pushed)10 kΩ or higher If the result is not as specified, replace the trip switch (light control rheostat).
TEXT IN ILLUSTRATION*1 Up Switch *2 Down Switch *a Component without harness connected
{Trip Switch (Light Control Rheostat)} Apply battery voltage to the connector and check the illumination condition.
OK
Measurement Condition Specified Condition Battery positive (+) → Terminal 8 (ILL+)
Battery negative (-) → Terminal 6 (ILL-)Illuminates If the result is not as specified, replace the trip switch (light control rheostat).
TEXT IN ILLUSTRATION*a Component without harness connected
{Trip Switch (Light Control Rheostat)}
- Measure the resistance according to the value(s) in the table below.