Entire Combination Meter does not Operate [08/2014 - ]: Procedure
- CHECK HARNESS AND CONNECTOR (COMBINATION METER ASSEMBLY CIRCUIT)
- Disconnect the H19 connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition H19-9 (E2) - Body ground Always Below 1 Ω H19-33 (EP) - Body ground Always Below 1 Ω - Measure the voltage according to the value(s) in the table below.
Standard Voltage
Tester Connection Condition Specified Condition H19-21 (IG2) - Body ground Power switch off Below 1 V Power switch on (IG) 11 to 14 V H19-22 (B) - Body ground Power switch off 11 to 14 V TEXT IN ILLUSTRATION*a Front view of wire harness connector
(to Combination Meter Assembly)
Result: OK
OK
REPLACE COMBINATION METER ASSEMBLY
(See article. Refer to REMOVAL [08/2014 - ] )
Result: NG
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
- Disconnect the H19 connector.