Installation [04/2013 - 10/2017]: Procedure
- INSTALL STARTER ASSEMBLY
- Install the starter assembly with the 2 bolts.
Torque: 58 N*m (591 kgf*cm, 43 ft.*lbf)
- Connect the wire harness, install the nut and close the terminal cap.
Torque: 9.8 N*m (100 kgf*cm, 87 in.*lbf)
- Connect the starter connector.
- Install the starter assembly with the 2 bolts.
- INSTALL EXHAUST MANIFOLD SUB-ASSEMBLY LH(TWC: Front Catalyst)
Refer to INSTALLATION [04/2013 - 10/2016] , or refer to INSTALLATION [10/2016 - 10/2017]
- CONNECT CABLE TO NEGATIVE BATTERY TERMINAL NOTE:
When disconnecting the cable, some systems need to be initialized after the cable is reconnected.
Refer to INITIALIZATION [04/2013 - 06/2014] , or refer to INITIALIZATION [06/2014 - 08/2015] , or refer to INITIALIZATION [08/2015 - 10/2016] , or refer to INITIALIZATION [10/2016 - 10/2017]