Inspection [08/2019 - ]: Procedure
- INSPECT COMBINATION SWITCH ASSEMBLY
- Measure the resistance according to the value(s) in the table below.
*a Component without harness connected
(Combination Switch Assembly)Standard Resistance
Tester Connection Switch Condition Specified Condition 1 (A/B) - 3 (E) ODO/TRIP switch on (Pushed) Below 1 Ω ODO/TRIP switch off (Not pushed) 10 kΩ or higher If the result is not as specified, replace the combination switch assembly.
- Inspect the switch illumination.
- Apply battery voltage between the terminals of the light and check the operation of the light.
OK
Measurement Condition Specified Condition Battery positive (+) → Terminal 8 (ILL+)
Battery negative (-) → Terminal 6 (ILL-)Illuminates If the result is not as specified, replace the combination switch assembly.
- Apply battery voltage between the terminals of the light and check the operation of the light.
- Measure the resistance according to the value(s) in the table below.