LEMON Manuals: Even more car manuals for everyone
Home >> Lexus >> 2016 >> GS F >> Repair and Diagnosis >> Accessories & Equipment >> Gauges & Instrument Panels >> Meter / Gauge / Display - Service Information >> Combination Meter >> Installation [10/2015 - ] >> Procedure

Installation [10/2015 - ]: Procedure

  1. INSTALL COMBINATION METER ASSEMBLY 
    1. Connect the 3 connectors.
      GTY656647Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
    2. Engage the clamp.
    3. Install the combination meter assembly with the 4 screws.
  2. INSTALL INSTRUMENT CLUSTER FINISH PANEL SUB-ASSEMBLY 

    Refer to PROCEDURE - Step 22

  3. INSTALL INSTRUMENT CLUSTER FINISH PANEL ASSEMBLY 

    Refer to PROCEDURE - Step 23

  4. INSTALL NO. 1 INSTRUMENT PANEL SAFETY PAD SUB-ASSEMBLY 

    Refer to INSTALLATION [10/2015 - ]

  5. CONNECT CABLE TO NEGATIVE BATTERY TERMINAL 

    Refer to PROCEDURE - Step 2

    NOTE:

    When disconnecting the cable, some systems need to be initialized after the cable is reconnected.

    Refer to INITIALIZATION [10/2015 - 09/2016] , or Refer to INITIALIZATION [09/2016 - 09/2017] , or Refer to INITIALIZATION [09/2017 - ]

  6. CUSTOMIZE POWER TILT AND POWER TELESCOPIC STEERING COLUMN SYSTEM 

    Refer to PROCEDURE - Step 15