Switch Lights of Remote Touch do not Illuminate [10/2014 - 09/2017]: Procedure
- CHECK HARNESS AND CONNECTOR (REMOTE OPERATION CONTROLLER ASSEMBLY - BATTERY)
- Disconnect the remote operation controller assembly connector.
*a Front view of wire harness connector
(to Remote Operation Controller Assembly) - Measure the voltage according to the value(s) in the table below.
Standard Voltage
Tester Connection Switch Condition Specified Condition I132-1 (ILL+) - Body ground Power switch off, light control switch in tail or head position 11 to 14 V Result
Proceed to OK NG
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
Result:
OK
See step 2
- Disconnect the remote operation controller assembly connector.
- CHECK HARNESS AND CONNECTOR (REMOTE OPERATION CONTROLLER ASSEMBLY - COMBINATION METER ASSEMBLY)
- Disconnect the I132 remote operation controller assembly connector.
- Disconnect the I10 combination meter assembly connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition I132-8 (ILL-) - I10-39 (ILL-) Always Below 1 Ω I132-8 (ILL-) or I10-39 (ILL-) - Body ground Always 10 kΩ or higher Result
Proceed to OK NG
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
Result:
OK
See step 3
- CHECK REMOTE OPERATION CONTROLLER ASSEMBLY
- Replace the remote operation controller assembly.
Refer to REMOVAL [10/2014 - 09/2017]
- Check if the switch illumination turns on.
OK
The switch illumination turns on when the light control switch is in the tail or head position.
Result
Proceed to OK NG
Result:
OK
END (REMOTE OPERATION CONTROLLER ASSEMBLY IS DEFECTIVE)
Result:
NG
GO TO METER / GAUGE SYSTEM. Refer to HOW TO PROCEED WITH TROUBLESHOOTING [10/2014 - ]
- Replace the remote operation controller assembly.