Home >> Lexus >> 2015 >> NX 200t Base, AWD >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 5 (Automatic Transmission (U661E) - Diagnostic Codes (2 Of 2) & Circuit Tests) >> Automatic Transaxle System >> DTC P2807-7F: Pressure Control Solenoid "G" Actuator Stuck Off [10/2014 - ] >> Typical Malfunction Thresholds

Typical Malfunction Thresholds

WARNING: This page is about a different variant/trim than selected.

[OFF malfunction] 

  1. One of the following conditions is met: OFF malfunction (A), (B) or (C)
    OFF MALFUNCTION (A)

    Turbine speed - Output speed x 3rd gear ratio 1000 rpm or more
    OFF MALFUNCTION (B)

    Turbine speed - Output speed x 5th gear ratio 1000 rpm or more
    OFF MALFUNCTION (C)

    Turbine speed / Output speed when output speed less than 1000 rpm 3.304 to 7.724

[ON malfunction] 

  1. Both of the following conditions are met: ON malfunction (A), (B) or (C) and ON malfunction (D)

    2 detections are necessary per driving cycle:

    1st detection: temporary flag ON

    2nd detection: pending fault code ON

    ON MALFUNCTION (A) AND (B)

    Turbine speed / Output speed when output speed less than 1000 rpm 1.399 to 1.649
    ON MALFUNCTION (C)

    Turbine speed / Output speed when output speed less than 1000 rpm 0.705 to 0.836
    ON MALFUNCTION (D)

    Turbine speed / Output speed when output speed less than 1000 rpm 0.998 to 1.138