Entire Combination Meter does not Operate: Procedure
- INSPECT COMBINATION METER ASSEMBLY
- Disconnect the F15 and F16 connectors.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition F15-16 (E2) - Body ground Always Below 1 Ω F16-6 (ES) - Body ground Always Below 1 Ω - Measure the voltage according to the value(s) in the table below.
Standard Voltage
Tester Connection Condition Specified Condition F16-1 (IG+) - Body ground Engine switch on (IG) 11 to 14 V F16-13 (B) - Body ground Always 11 to 14 V TEXT IN ILLUSTRATION*1 Front view of wire harness connector
(to Combination Meter Assembly)*2 Front view of wire harness connector
(to Combination Meter Assembly)
NG → REPAIR OR REPLACE HARNESS OR CONNECTOR
OK → See step 2
- Disconnect the F15 and F16 connectors.
- REPLACE COMBINATION METER ASSEMBLY. Refer to REMOVAL [03/2012 - 07/2012]