DTC B1500: Fuel Sender Open Detected: Procedure
- READ VALUE USING TECHSTREAM (FUEL INPUT)
- Connect the Techstream to the DLC3.
- Turn the engine switch on (IG).
- Turn the Techstream on.
- Enter the following menus: Body Electrical / Combination Meter / Data List.
- Check the values by referring to the table below.COMBINATION METER
Tester Display Measurement Item/Range Normal Condition Diagnostic Note Fuel Input Fuel input signal/Min.: 0, Max.: 127.5 Current fuel level displayed Unit: Liter Result
Result Proceed to Fuel level data can be displayed on the Techstream and DTC B1500 is output. A Fuel level data cannot be displayed on the Techstream. B
B → See step 2
A → See step 6
- INSPECT COMBINATION METER ASSEMBLY
- Disconnect the F16 connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition F16-16 (FR) - F16-17 (FE) Always 13.5 to 414.5 Ω TEXT IN ILLUSTRATION*1 Front view of wire harness connector
(to Combination Meter Assembly)
NG → See step 3
OK → See step 6
- Disconnect the F16 connector.
- CHECK HARNESS AND CONNECTOR (COMBINATION METER ASSEMBLY - FUEL SENDER GAUGE ASSEMBLY)
- Disconnect the P11 connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition F16-16 (FR) - P11-2 (S) Always Below 1 Ω F16-16 (FR) - Body ground Always 10 kΩ or higher F16-17 (FE) - P11-3 (FE) Always Below 1 Ω F16-17 (FE) - Body ground Always 10 kΩ or higher TEXT IN ILLUSTRATION*1 Front view of wire harness connector
(to Combination Meter Assembly)*2 Front view of wire harness connector
(to Fuel Suction Pump and Gauge Assembly)
NG → REPAIR OR REPLACE HARNESS OR CONNECTOR
OK: Go to next step
- Disconnect the P11 connector.
- INSPECT FUEL SUCTION PUMP AND GAUGE ASSEMBLY
- Remove the fuel sender gauge assembly. Refer to REMOVAL [03/2012 - ]
.
- Check that the float moves smoothly between E and F.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition 1 - 2 Float level is F (upper) 13.5 to 16.5 Ω 1 - 2 Float level is between F (upper) and E (lower) 13.5 to 414.5 Ω (Gradually changes) 1 - 2 Float level is E (lower) 405.5 to 414.5 Ω TEXT IN ILLUSTRATION*1 Front view of wire harness connector
(to Fuel Sender Gauge Assembly)
NG → See step 7
OK: Go to next step
- Remove the fuel sender gauge assembly. Refer to REMOVAL [03/2012 - ]
.
- CHECK FUEL SUCTION PUMP AND GAUGE ASSEMBLY
- Visually check for deformation on the fuel suction pump and gauge assembly connector.
OK
There is no deformation.
NG → See step 8
OK → See step 6
- Visually check for deformation on the fuel suction pump and gauge assembly connector.
- REPLACE COMBINATION METER ASSEMBLY. Refer to REMOVAL [03/2012 - 07/2012]
- REPLACE FUEL SENDER GAUGE ASSEMBLY (for 2GR-FE). Refer to REMOVAL [03/2012 - ]
- REPLACE FUEL SUCTION PUMP AND GAUGE ASSEMBLY (for 2GR-FE). Refer to REMOVAL [03/2012 - ]