Odo/Trip Switch Malfunction: Procedure
- READ VALUE USING TECHSTREAM (TRIP SWITCH)
- Operate the Techstream according to the display and select "Data List".
OK
Switch condition (ON/OFF) can be switched by actual operation.
COMBINATION METERTester Display Measurement Item/Range Normal Condition Diagnostic Note ODO/TRIP Change SW Trip switch (ODO/TRIP switch) condition / ON or OFF ON: Trip switch (ODO/TRIP switch) pushed
OFF: Trip switch (ODO/TRIP switch) not pushed- Trip Reset SW Trip switch (RESET switch) condition / ON or OFF ON: Trip switch (ODO/TRIP switch) pushed
OFF: Trip switch (ODO/TRIP switch) not pushed-
NG → See step 2
OK → See step 4
- Operate the Techstream according to the display and select "Data List".
- INSPECT TRIP SWITCH
- Remove the trip switch. Refer to REMOVAL [09/2012 - ]
.
- Measure the resistance according to the value(s) in the table below.
Standard resistance
Tester Connection Switch Condition Specified Condition 5 (RSET) - 6 (E) RESET switch ON (Pushed) Below 1 Ω RESET switch OFF (Not pushed) 10 kΩ or higher 7 (A/B) - 6 (E) ODO/TRIP switch ON (Pushed) Below 1 Ω ODO/TRIP switch OFF (Not pushed) 10 kΩ or higher
NG → See step 5
OK: Go to next step
- Remove the trip switch. Refer to REMOVAL [09/2012 - ]
.
- CHECK HARNESS AND CONNECTOR (NO. 1 METER ECU - TRIP SWITCH AND BODY GROUND)
- Disconnect the L10 ECU connector.
- Disconnect the L45 switch connector.
- Measure the resistance according to the value(s) in the table below.
Standard resistance
Tester Connection Condition Specified Condition L10-4 (A/B) - L45-7 (A/B) Always Below 1 Ω L10-5 (RSET) - L45-5 (RSET) L45-6 (E) - Body ground L10-4 (A/B) or L45-7 (A/B) - Body ground Always 10 kΩ or higher L10-5 (RSET) or L45-5 (RSET) - Body ground
NG → REPAIR OR REPLACE HARNESS OR CONNECTOR
OK → See step 6
- Disconnect the L10 ECU connector.
- REPLACE NO. 1 METER ECU. Refer to DISASSEMBLY [09/2012 - ]
- REPLACE TRIP SWITCH. Refer to REMOVAL [09/2012 - ]
- REPLACE NO. 1 METER ECU. Refer to DISASSEMBLY [09/2012 - ]