Meter Illumination is Always Dark: Procedure
- CHECK CAN COMMUNICATION SYSTEM
- Check for DTC. Refer to DIAGNOSIS SYSTEM [09/2012 - ]
.RESULT
Result Proceed to DTC is not output A CAN communication system DTC is output B Lighting system DTC (B1244) is output C
B → See step 5
C → See step 6
A: Go to next step
- Check for DTC. Refer to DIAGNOSIS SYSTEM [09/2012 - ]
.
- PERFORM ACTIVE TEST USING TECHSTREAM (DIMMER SWITCH)
- Operate the Techstream according to the display and select "Active Test".
OK
Meter illumination is dimmed when the dimmer switch is ON.
MAIN BODYTester Display Test Part Control Range Dimmer signal Dimmer switch ON or OFF HINT:
Refer to the sensitivity setting in the customization table of the automatic light control system. Refer to CUSTOMIZE PARAMETERS [09/2012 - ] .
NG → See step 3
OK → See step 7
- Operate the Techstream according to the display and select "Active Test".
- REPLACE NO. 1 METER ECU
- Temporarily replace the No. 1 meter ECU with a new one. Refer to DISASSEMBLY [09/2012 - ] .
NEXT: Go to next step
- CHECK NO. 1 METER ECU
- Check that the operation of the No. 1 meter ECU returns to normal. Refer to OPERATION CHECK [09/2012 - ]
.
OK
Operation of No. 1 meter ECU returns to normal.
NG → REPLACE MAIN BODY ECU (DRIVER SIDE JUNCTION BLOCK)
OK → END (NO. 1 METER ECU IS DEFECTIVE)
- Check that the operation of the No. 1 meter ECU returns to normal. Refer to OPERATION CHECK [09/2012 - ]
.
- Go to CAN COMMUNICATION SYSTEM. Refer to PRECAUTION [09/2012 - ]
- Go to LIGHTING SYSTEM. Refer to DIAGNOSTIC TROUBLE CODE CHART [09/2012 - ]
- CHECK LIGHTING SETTING. Refer to CUSTOMIZE PARAMETERS [09/2012 - ]