LEMON Manuals: Even more car manuals for everyone
Home >> Lexus >> 2013 >> GX 460 Base >> Repair and Diagnosis >> Accessories & Equipment >> Gauges & Instrument Panels >> Meter / Gauge / Display (Diagnostic Codes & Symptom Tests) >> Meter / Gauge System >> Symptom Tests >> Operating Light Control Rheostat does not Change Light Brightness >> Procedure

Operating Light Control Rheostat does not Change Light Brightness: Procedure

  1. SYSTEM CHECK 
    1. Confirm the symptoms.
      RESULT

      Result Proceed to
      Meter illumination does not change when operating light control switch A
      Dimmer function cannot be canceled B

    B → See step   5 

    A: Go to next step 

  2. READ VALUE USING TECHSTREAM (LIGHT CONTROL UP SW, LIGHT CONTROL DOWN SW) 
    1. Connect the Techstream to the DLC3.
    2. Turn the engine switch on (IG).
    3. Turn the Techstream on.
    4. Enter the following menus: Body Electrical / Combination Meter / Data List.
    5. Check the values by referring to the table below.
      COMBINATION METER

      Tester Display Measurement Item/Range Normal Condition Diagnostic Note
      Light Control Up SW Light control rheostat up switch/OFF or ON OFF: Light control rheostat up switch not pressed -
      ON: Light control rheostat up switch pressed
      Light Control Down SW Light control rheostat down switch/ OFF or ON OFF: Light control rheostat down switch not pressed -
      ON: Light control rheostat down switch pressed

      OK

      The value displayed on the Techstream changes with the actual rheostat switch operation.

    NG → See step   3 

    OK → See step   7 

  3. INSPECT LIGHT CONTROL RHEOSTAT 
    1. Remove the light control rheostat. Refer to REMOVAL [06/2012 - ] .
      GTY349288Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
    2. Measure the resistance according to the value(s) in the table below.
      STANDARD RESISTANCE

      Tester Connection Switch Condition Specified Condition
      2 (UP) - 8 (E) Light control rheostat up switch pressed Below 1 Ω
      Light control rheostat up switch not pressed 10 kΩ or higher
      1 (DOWN) - 8 (E) Light control rheostat down switch pressed Below 1 Ω
      Light control rheostat down switch not pressed 10 kΩ or higher
      TEXT IN ILLUSTRATION

      *a Component without harness connected
      (Light Control Rheostat)
      *b Light control rheostat up switch
      *c Light control rheostat down switch

    NG → See step   8 

    OK: Go to next step 

  4. CHECK HARNESS AND CONNECTOR (COMBINATION METER ASSEMBLY - LIGHT CONTROL RHEOSTAT AND BODY GROUND) 
    1. Disconnect the G3 meter connector.
    2. Disconnect the G8 light control rheostat connector.
    3. Measure the resistance according to the value(s) in the table below.
      STANDARD RESISTANCE

      Tester Connection Condition Specified Condition
      G3-6 (RHUP) - G8-2 (UP) Always Below 1 Ω
      G3-6 (RHUP) - Body ground Always 10 kΩ or higher
      G3-7 (RHDW) - G8-1 (DOWN) Always Below 1 Ω
      G3-7 (RHDW) - Body ground Always 10 kΩ or higher
      G8-8 (E) - Body ground Always Below 1 Ω

    NG → REPAIR OR REPLACE HARNESS OR CONNECTOR 

    OK → See step   7 

  5. INSPECT LIGHT CONTROL RHEOSTAT 
    1. Remove the light control rheostat. Refer to REMOVAL [06/2012 - ] .
      GTY407896Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
    2. Measure the resistance according to the value(s) in the table below.
      STANDARD RESISTANCE

      Tester Connection Switch Condition Specified Condition
      2 (UP) - 8 (E) Light control rheostat up switch pressed Below 1 Ω
      Light control rheostat up switch not pressed 10 kΩ or higher
      TEXT IN ILLUSTRATION

      *a Component without harness connected
      (Light Control Rheostat)
      *b Light control rheostat up switch
      *c Light control rheostat down switch

    NG → See step   8 

    OK: Go to next step 

  6. CHECK HARNESS AND CONNECTOR (COMBINATION METER - LIGHT CONTROL RHEOSTAT) 
    1. Disconnect the G3 meter connector.
    2. Disconnect the G8 light control rheostat connector.
    3. Measure the resistance according to the value(s) in the table below.
      STANDARD RESISTANCE

      Tester Connection Condition Specified Condition
      G3-6 (RHUP) - G8-2 (UP) Always Below 1 Ω
      G3-6 (RHUP) - Body ground Always 10 kΩ or higher

    NG → REPAIR OR REPLACE HARNESS OR CONNECTOR 

    OK → See step   7 

  7. REPLACE COMBINATION METER ASSEMBLY. Refer to  REMOVAL [06/2012 - ] 
  8. REPLACE LIGHT CONTROL RHEOSTAT. Refer to  REMOVAL [06/2012 - ]