Operating Light Control Rheostat does not Change Light Brightness: Procedure
- SYSTEM CHECK
- Confirm the symptoms.RESULT
Result Proceed to Meter illumination does not change when operating light control switch A Dimmer function cannot be canceled B
B → See step 5
A: Go to next step
- Confirm the symptoms.
- READ VALUE USING TECHSTREAM (LIGHT CONTROL UP SW, LIGHT CONTROL DOWN SW)
- Connect the Techstream to the DLC3.
- Turn the engine switch on (IG).
- Turn the Techstream on.
- Enter the following menus: Body Electrical / Combination Meter / Data List.
- Check the values by referring to the table below.COMBINATION METER
Tester Display Measurement Item/Range Normal Condition Diagnostic Note Light Control Up SW Light control rheostat up switch/OFF or ON OFF: Light control rheostat up switch not pressed - ON: Light control rheostat up switch pressed Light Control Down SW Light control rheostat down switch/ OFF or ON OFF: Light control rheostat down switch not pressed - ON: Light control rheostat down switch pressed OK
The value displayed on the Techstream changes with the actual rheostat switch operation.
NG → See step 3
OK → See step 7
- INSPECT LIGHT CONTROL RHEOSTAT
- Remove the light control rheostat. Refer to REMOVAL [06/2012 - ]
.
- Measure the resistance according to the value(s) in the table below.STANDARD RESISTANCE
Tester Connection Switch Condition Specified Condition 2 (UP) - 8 (E) Light control rheostat up switch pressed Below 1 Ω Light control rheostat up switch not pressed 10 kΩ or higher 1 (DOWN) - 8 (E) Light control rheostat down switch pressed Below 1 Ω Light control rheostat down switch not pressed 10 kΩ or higher TEXT IN ILLUSTRATION*a Component without harness connected
(Light Control Rheostat)*b Light control rheostat up switch *c Light control rheostat down switch
NG → See step 8
OK: Go to next step
- Remove the light control rheostat. Refer to REMOVAL [06/2012 - ]
.
- CHECK HARNESS AND CONNECTOR (COMBINATION METER ASSEMBLY - LIGHT CONTROL RHEOSTAT AND BODY GROUND)
- Disconnect the G3 meter connector.
- Disconnect the G8 light control rheostat connector.
- Measure the resistance according to the value(s) in the table below.STANDARD RESISTANCE
Tester Connection Condition Specified Condition G3-6 (RHUP) - G8-2 (UP) Always Below 1 Ω G3-6 (RHUP) - Body ground Always 10 kΩ or higher G3-7 (RHDW) - G8-1 (DOWN) Always Below 1 Ω G3-7 (RHDW) - Body ground Always 10 kΩ or higher G8-8 (E) - Body ground Always Below 1 Ω
NG → REPAIR OR REPLACE HARNESS OR CONNECTOR
OK → See step 7
- INSPECT LIGHT CONTROL RHEOSTAT
- Remove the light control rheostat. Refer to REMOVAL [06/2012 - ]
.
- Measure the resistance according to the value(s) in the table below.STANDARD RESISTANCE
Tester Connection Switch Condition Specified Condition 2 (UP) - 8 (E) Light control rheostat up switch pressed Below 1 Ω Light control rheostat up switch not pressed 10 kΩ or higher TEXT IN ILLUSTRATION*a Component without harness connected
(Light Control Rheostat)*b Light control rheostat up switch *c Light control rheostat down switch
NG → See step 8
OK: Go to next step
- Remove the light control rheostat. Refer to REMOVAL [06/2012 - ]
.
- CHECK HARNESS AND CONNECTOR (COMBINATION METER - LIGHT CONTROL RHEOSTAT)
- Disconnect the G3 meter connector.
- Disconnect the G8 light control rheostat connector.
- Measure the resistance according to the value(s) in the table below.STANDARD RESISTANCE
Tester Connection Condition Specified Condition G3-6 (RHUP) - G8-2 (UP) Always Below 1 Ω G3-6 (RHUP) - Body ground Always 10 kΩ or higher
NG → REPAIR OR REPLACE HARNESS OR CONNECTOR
OK → See step 7
- REPLACE COMBINATION METER ASSEMBLY. Refer to REMOVAL [06/2012 - ]
- REPLACE LIGHT CONTROL RHEOSTAT. Refer to REMOVAL [06/2012 - ]