Accessory Meter does not Illuminate: Procedure
- CHECK HARNESS AND CONNECTOR (ACCESSORY METER ASSEMBLY CIRCUIT)
- Disconnect the H26 accessory meter connector.
- Measure the voltage according to the value(s) in the table below.STANDARD VOLTAGE
Tester Connection Condition Specified Condition H26-1 (IG) - Body ground Engine switch on (IG) 11 to 14 V H26-9 (+B) - Body ground Always 11 to 14 V - Measure the resistance according to the value(s) in the table below.STANDARD RESISTANCE
Tester Connection Condition Specified Condition H26-16 (GND) - Body ground Always Below 1 Ω TEXT IN ILLUSTRATION*a Front view of wire harness connector
(to Accessory Meter)
NG → REPAIR OR REPLACE HARNESS OR CONNECTOR
OK → See step 2
- Disconnect the H26 accessory meter connector.
- REPLACE ACCESSORY METER ASSEMBLY. Refer to REMOVAL [06/2012 - ]