LEMON Manuals: Even more car manuals for everyone
Home >> Lexus >> 2012 >> LS 600hL >> Repair and Diagnosis >> Accessories & Equipment >> Gauges & Instrument Panels >> Meter & Gauge System (Diagnostic Codes & Symptom Tests) >> Meter / Gauge System >> Symptom Tests >> Operating Light Control Rheostat does not Change Light Brightness >> Procedure

Operating Light Control Rheostat does not Change Light Brightness: Procedure

  1. READ VALUE USING TECHSTREAM (LIGHT CONTROL RHEOSTAT) 
    1. Operate the Techstream according to the display and select "Data List".
      COMBINATION METER:

      Item Measurement Item / Range (Display) Normal Condition Diagnostic Note
      Light Control Up Switch Light control rheostat (UP) switch / ON or OFF ON: Light control rheostat (UP) switch pushed
      OFF: Light control rheostat (UP) switch not pushed
      -
      Light Control Down Switch Light control rheostat (DOWN) switch / ON or OFF ON: Light control rheostat (DOWN) switch pushed
      OFF: Light control rheostat (DOWN) switch not pushed
      -

      OK

      Switch condition (ON/OFF) can be switched by actual operation.

    NG → See step   2 

    OK → See step   4 

  2. INSPECT LIGHT CONTROL RHEOSTAT 
    Fig 1: Light Control Rheostat
    GTY395418Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
    1. Remove the rheostat. Refer to REMOVAL .
    2. Measure the resistance according to the value(s) in the table below.

      Standard resistance

      Tester Connection Switch Condition Specified Condition
      3 (UP) - 5 (E) UP switch is pushed Below 200 Ω
      UP switch is not pushed 1 MΩ or higher
      7 (DOWN) - 5 (E) DOWN switch is pushed Below 200 Ω
      DOWN switch is not pushed 1 MΩ or higher

    NG → See step   5 

    OK: Go to next step 

  3. CHECK HARNESS AND CONNECTOR (COMBINATION METER ASSEMBLY - LIGHT CONTROL RHEOSTAT AND BODY GROUND) 
    Fig 2: Identifying L8 Rheostat And L10 Meter Connectors
    GTY267162Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
    1. Disconnect the L10 meter connector.
    2. Disconnect the L8 rheostat connector.
    3. Measure the resistance according to the value(s) in the table below.

      Standard resistance

      Tester Connection Condition Specified Condition
      L10-8 (RHUP) - L8-3 (UP) Always Below 1 Ω
      L10-7 (RHDW) - L8-7 (DOWN)
      L8-5 (E) - Body ground
      L10-8 (RHUP) or L8-3 (UP) - Body ground Always 10 kΩ or higher
      L10-7 (RHDW) or L8-7 (DOWN) - Body ground

    NG → REPAIR OR REPLACE HARNESS OR CONNECTOR 

    OK → See step   4 

  4. REPLACE COMBINATION METER ASSEMBLY. Refer to  DISASSEMBLY 
  5. REPLACE LIGHT CONTROL RHEOSTAT. Refer to  REMOVAL