ODO/Trip Switch Malfunction: Procedure
- READ VALUE USING TECHSTREAM (ODO/TRIP CHANGE SW)
- Connect the Techstream to the DLC3.
- Turn the engine switch on (IG).
- Turn the Techstream on.
- Enter the following menus: Body Electrical / Combination Meter / Data List.
- Check the values by referring to the table below.COMBINATION METER
Tester Display Measurement Item/Range Normal Condition Diagnostic Note ODO/TRIP Change SW ODO/TRIP change switch/OFF or ON OFF: ODO/TRIP change switch released - ON: ODO/TRIP change switch pressed OK
The value displayed on the Techstream changes with the actual ODO/TRIP change switch operation.
NG → See step 2
OK → See step 5
- INSPECT LIGHT CONTROL RHEOSTAT
- Remove the light control rheostat.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Switch Condition Specified Condition 2 (A/B) - 5 (E) ODO/TRIP change switch pressed Below 1 Ω 2 (A/B) - 5 (E) ODO/TRIP change switch not pressed 10 kΩ or higher TEXT IN ILLUSTRATION*1 Component without harness connected
(Light Control Rheostat)
NG → See step 4
OK: Go to next step
- CHECK HARNESS AND CONNECTOR (COMBINATION METER ASSEMBLY - LIGHT CONTROL RHEOSTAT)
- Disconnect the F16 connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition F16-9 (A/B) - F6-2 (A/B) Always Below 1 Ω F16-9 (A/B) - Body ground Always 10 kΩ or higher TEXT IN ILLUSTRATION*1 Front view of wire harness connector
(to Combination Meter Assembly)*2 Front view of wire harness connector
(to Light Control Rheostat)
NG → REPAIR OR REPLACE HARNESS OR CONNECTOR
OK → See step 5
- REPLACE LIGHT CONTROL RHEOSTAT. Refer to REMOVAL