Switch Operation of Remote Touch not Accepted: Procedure

  1. CHECK START DIAGNOSTIC MODE 
    1. Activate diagnostic mode and check if the "Service Menu" screen can be displayed. Refer to OPERATION CHECK .

      OK

      Diagnostic mode can be activated.

    NG → See step   3 

    OK: Go to next step 

  2. CHECK PANEL SWITCH (OPERATION CHECK) 
    1. Display the "Panel&Steering Switch Check Mode" screen. Refer to OPERATION CHECK .
      Fig 1: Identifying "Panel & Steering Switch Check Mode" screen
      GTY261022Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
    2. Press each switch on the remote touch and check that the switch name is displayed on the screen.

      OK

      Pressing each switch displays its name on the screen.

      TEXT IN ILLUSTRATION

      *1 Push switch name

    NG → See step   3 

    OK → See step   5 

  3. REMOTE TOUCH SELF CHECK (SWITCH OPERATION CHECK) 
    1. Activate self check mode. Refer to OPERATION CHECK .
    2. Check switch operation.
      Fig 2: Switch Illumination & Switch Knob
      GTY357692Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
      1. Move the remote touch switch knob to the lower left.
      2. Check that the "MAP/VOICE" and "MENU" switches illuminate when each switch on the remote touch is pressed.

        Result

        Result Proceed to
        Self check mode cannot be activated. A
        Some switches do not turn on the "MAP/VOICE" and "MENU" switch illumination when they are pressed.
        All switches turn on the "MAP/VOICE" and "MENU" switch illumination when they are pressed. B
        TEXT IN ILLUSTRATION

        *1 Switch Illumination
        *2 Switch Knob

    B → See step   5 

    A: Go to next step 

  4. REPLACE INTEGRATION PANEL SUB-ASSEMBLY 
    1. Replace the integration panel sub-assembly. Refer to REMOVAL .
    2. Check that each switch operation on the "remote switch" is accepted normally.

      OK

      Each switch operation is accepted normally.

    NG → See step   6 

    OK → END 

  5. REPLACE DISPLAY AND NAVIGATION MODULE DISPLAY. Refer to  REMOVAL 
  6. REPLACE REMOTE TOUCH (REMOTE OPERATION BOARD). Refer to  DISASSEMBLY