DTC P2759: Torque Converter Clutch Pressure Control Solenoid Control Circuit Electrical (Shift Solenoid Valve SLU) (TO 08/2009): Procedure
- INSPECT TRANSMISSION WIRE (SLU)
- Remove the TCM from the transaxle.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition 11 (SLU+) - 5 (SLU-) 20°C (68°F) 5.0 to 5.6 Ω 11 (SLU+) - Body ground or other terminals Always 10 kΩ or higher 5 (SLU-) - Body ground or other terminals Always 10 kΩ or higher 11 (SLU+) - All other terminals except 5 (SLU-) Always 10 kΩ or higher 5 (SLU-) - All other terminals except 11 (SLU+) Always 10 kΩ or higher Result
Result Proceed to OK B NG A
B → See step 4
A: Go to next step
- INSPECT SHIFT SOLENOID VALVE SLU
- Remove shift solenoid valve SLU.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition 1 - 2 20°C (68°F) 5.0 to 5.6 Ω TEXT IN ILLUSTRATION*1 Shift Solenoid Valve SLU - Connect a battery positive (+) lead with a 21 W bulb to terminal 2 and a negative (-) lead to terminal 1 of the solenoid valve connector. Then check that the valve moves and makes an operating sound.
OK
Valve moves and makes an operating sound.
NG → See step 5
OK → See step 3
- REPLACE TRANSMISSION WIRE. Refer to REMOVAL
- REPLACE TCM. Refer to REMOVAL
- REPLACE SHIFT SOLENOID VALVE SLU. Refer to REMOVAL