DTC P2799-859: Auxiliary Transmission Fluid Pump Control Circuit High: Procedure
- CHECK HYBRID VEHICLE CONTROL ECU (CHECK WAVEFORM)
- Connect an oscilloscope to the hybrid vehicle control ECU terminals specified in the table below, and measure the waveform.
Item Contents Terminal A74-33 (OPST) - A75-7 (E1) Equipment Setting 5 V/DIV., 5 ms./DIV. Condition Power switch on (IG) Result
Result Proceed to Waveform is flat, and is stuck on the +B side. A Normal B
B → See step 13
A: Go to next step
- Connect an oscilloscope to the hybrid vehicle control ECU terminals specified in the table below, and measure the waveform.
- CHECK CONNECTOR CONNECTION CONDITION (OIL PUMP MOTOR CONTROLLER CONNECTOR) NOTE:
Before disconnecting the connectors, confirm that they are properly connected by checking that the locking claws are engaged and that the connectors cannot be pulled out.
- Check the connections of the oil pump motor controller connectors.
OK
The connectors are connected securely and there are no contact problems.
HINT:
For connector A, when connecting it, insert it with the locking lever in the raised position. Rotate the lever downward and make sure that the connector is pulled into its socket. When the locking lever is in its fully closed position, a click will be heard as its locking claws engage. After the click is heard, pull up on the connector to confirm that it is properly connected.
NG → CONNECT SECURELY
OK: Go to next step
- Check the connections of the oil pump motor controller connectors.
- CHECK CONNECTOR CONNECTION CONDITION (HYBRID VEHICLE CONTROL ECU CONNECTOR)
- Check the connections of the hybrid vehicle control ECU connectors.
OK
The connectors are connected securely and there are no contact problems.
NG → CONNECT SECURELY
OK: Go to next step
- Check the connections of the hybrid vehicle control ECU connectors.
- CHECK OIL PUMP MOTOR CONTROLLER
- Turn the power switch off.
- Disconnect connector A78 from the oil pump motor controller.
- Turn the power switch on (IG).
- Measure the voltage according to the value(s) in the table below.
Standard voltage
Tester Connection Switch Condition Specified Condition A78-5 (+B) - Body ground Power switch on (IG) 11 to 14 V NOTE:Turning the power switch on (IG) with the oil pump motor controller connector disconnected causes other DTCs to be stored. Clear the DTCs after performing this inspection.
NG → See step 7
OK: Go to next step
- CHECK HARNESS AND CONNECTOR (HYBRID VEHICLE CONTROL ECU - OIL PUMP MOTOR CONTROLLER)
- Turn the power switch off.
- Disconnect connector A74 from the hybrid vehicle control ECU.
- Disconnect connector A78 from the oil pump motor controller.
- Turn the power switch on (IG).
- Measure the voltage according to the value(s) in the table below.
Standard voltage
Tester Connection Switch Condition Specified Condition A74-33 (OPST) - Body ground Power switch on (IG) Below 1 V NOTE:Turning the power switch on (IG) with the hybrid vehicle control ECU and oil pump motor controller connectors disconnected causes other DTCs to be stored. Clear the DTCs after performing this inspection.
- Turn the power switch off.
- Measure the resistance according to the value(s) in the table below.
Standard resistance (Check for open)
Tester Connection Switch Condition Specified Condition A74-33 (OPST) - A78-7 (OPST) Power switch off Below 1 Ω Standard resistance (Check for short)
Tester Connection Switch Condition Specified Condition A74-33 (OPST) or A78-7 (OPST) - Body ground and other terminals Power switch off 10 kΩ or higher
NG → REPAIR OR REPLACE HARNESS OR CONNECTOR
OK: Go to next step
- CHECK HYBRID VEHICLE CONTROL ECU
- Turn the power switch off.
- Measure the resistance according to the value(s) in the table below.
Standard resistance
Tester Connection Switch Condition Specified Condition A74-33 (OPST) - A76-1 (+B1) Power switch off 6.5 to 8.5 Ω
NG → See step 14
OK → See step 15
- CHECK FUSIBLE LINK BLOCK ASSEMBLY (OIL PMP)
- Check if there is an open circuit in the fusible link (OIL PMP) in the engine room No. 1 junction block.
OK
There is no open circuit in the fusible link (OIL PMP).
NG → REPLACE FUSIBLE LINK BLOCK ASSEMBLY
OK: Go to next step
- Check if there is an open circuit in the fusible link (OIL PMP) in the engine room No. 1 junction block.
- CHECK HARNESS AND CONNECTOR
- Turn the power switch off.
- Remove the OIL PMP relay from the engine room No. 5 relay block.
- Measure the resistance according to the value(s) in the table below.
Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
Standard resistance (Check for open)
Tester Connection Switch Condition Specified Condition Engine room No. 5 relay block OIL PMP relay terminal 3 - A78-5 (+B) Power switch off Below 1 Ω Engine room No. 5 relay block OIL PMP relay terminal 2 - Body ground Power switch off Below 1 Ω Standard resistance (Check for short)
Tester Connection Switch Condition Specified Condition Engine room No. 5 relay block OIL PMP relay terminal 3 - Body ground Power switch off 10 kΩ or higher
NG → REPAIR OR REPLACE HARNESS OR CONNECTOR
OK: Go to next step
- CHECK RELAY (OIL PMP)
- Measure the resistance according to the value(s) in the table below.
Standard resistance
Tester Connection Condition Specified Condition 1 - 2 Always 151 to 203 Ω 3 - 5 Auxiliary battery voltage is not applied between terminals 1 and 2. 10 kΩ or higher Auxiliary battery voltage is applied between terminals 1 and 2. Below 1 Ω
NG → See step 16
OK: Go to next step
- Measure the resistance according to the value(s) in the table below.
- CHECK HARNESS AND CONNECTOR
- Turn the power switch off.
- Measure the voltage according to the value(s) in the table below.
Standard voltage
Tester Connection Switch Condition Specified Condition Engine room No. 5 relay block OIL PMP relay terminal 5 - Body ground Power switch off 11 to 14 V
NG → REPAIR OR REPLACE HARNESS OR CONNECTOR
OK: Go to next step
- CHECK HYBRID VEHICLE CONTROL ECU
- Turn the power switch on (IG).
- Measure the voltage according to the value(s) in the table below.
Standard voltage
Tester Connection Switch Condition Specified Condition Engine room No. 5 relay block OIL PMP relay terminal 1 - Body ground Power switch on (IG) 11 to 14 V
NG → See step 12
OK → See step 14
- CHECK HARNESS AND CONNECTOR (HYBRID VEHICLE CONTROL ECU - ENGINE ROOM NO. 5 RELAY BLOCK)
- Turn the power switch off.
- Disconnect connector A74 from the hybrid vehicle control ECU.
- Measure the resistance according to the value(s) in the table below.
Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
Standard resistance (Check for open)
Tester Connection Switch Condition Specified Condition A74-24 (OPM2) - Engine room No. 5 relay block OIL PMP relay terminal 1 Power switch off Below 1 Ω Standard resistance (Check for short)
Tester Connection Switch Condition Specified Condition A74-24 (OPM2) or Engine room No. 5 relay block OIL PMP relay terminal 1 - Body ground Power switch off 10 kΩ or higher
NG → REPAIR OR REPLACE HARNESS OR CONNECTOR
OK → See step 14
- CHECK FOR INTERMITTENT PROBLEMS
- Check for intermittent problems. Refer to CHECK FOR INTERMITTENT PROBLEMS .
NG → REPAIR OR REPLACE MALFUNCTIONING PARTS, COMPONENT AND AREA
OK → See step 14
- REPLACE HYBRID VEHICLE CONTROL ECU. Refer to COMPONENTS
- REPLACE OIL PUMP MOTOR CONTROLLER. Refer to COMPONENTS
- REPLACE RELAY (OIL PMP). Refer to COMPONENTS