DTC B256D: Lock in Quarter Window Motor RH Circuit: Procedure
- INSPECT POWER WINDOW REGULATOR MOTOR ASSEMBLY RH
- Remove the power window regulator motor assembly RH.
- Apply battery voltage and check operation of the power window regulator motor.
OK
Measurement Condition Specified Condition Battery positive (+) → 1 (D)
Battery negative (-) → 2 (U)Motor gear rotates counterclockwise Battery positive (+) → 2 (U)
Battery negative (-) → 1 (D)Motor gear rotates clockwise TEXT IN ILLUSTRATION*1 Component without harness connected
(Power Window Regulator Motor Assembly RH)*2 Motor Gear *3 Clockwise *4 Counterclockwise
NG → REPLACE POWER WINDOW REGULATOR MOTOR ASSEMBLY RH
OK: Go to next step
- CHECK HARNESS AND CONNECTOR (POWER WINDOW REGULATOR MOTOR RH - SLIDING ROOF CONTROL ECU)
- Disconnect the P44 and P54 connectors.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition P54-12 (QWR+) - P54-11 (QWR-) Always 10 kΩ or higher P54-12 (QWR+) - Body ground Always 10 kΩ or higher P54-11 (QWR-) - Body ground Always 10 kΩ or higher TEXT IN ILLUSTRATION*1 Front view of wire harness connector
(to Sliding Roof Control ECU Assembly)
NG → REPAIR OR REPLACE HARNESS OR CONNECTOR
OK → REPLACE SLIDING ROOF CONTROL ECU ASSEMBLY