LEMON Manuals: Even more car manuals for everyone
Home >> Lexus >> 2010 >> IS 350 >> Repair and Diagnosis >> External Pages >> Different car >> Section 31 (Automatic Transmission (A760H) (Diagnostic Codes (P0500-U0100) & Circuit Tests)) >> Automatic Transmission System >> DTC P2759: Torque Converter Clutch Pressure Control Solenoid Control Circuit Electrical (Shift Solenoid Valve SLU) >> Inspection Procedure >> Procedure

Inspection Procedure: Procedure

WARNING: This page is about a different car, the 2010 Lexus IS 250. However, it is still accessible from the selected car via links, so may be relevant.
  1. INSPECT TRANSMISSION WIRE (SLU) 
    1. Disconnect the transmission wire connector from the transmission.
      Fig 1: Inspecting Transmission Wire (SLU)
      GTY135342Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
    2. Measure the resistance according to the value(s) in the table below.

      Standard resistance

      Tester Connection Specified Condition
      20°C (68°F)
      12 (SLU+) - 4 (SLU-) 5.0 to 5.6 Ω
    3. Measure the resistance according to the value(s) in the table below.

      Standard resistance (Check for short)

      Tester Connection Specified Condition
      12 (SLU+) - Body ground 10 kΩ or higher
      4 (SLU-) - Body ground

    NG → See step   3 

    OK: Go to next step 

  2. CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - ECM) 
    1. Connect the transmission wire connector to the transmission.
      Fig 2: Identifying ECM E4 Connector
      GTY114131Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
    2. Disconnect the ECM connector.
    3. Measure the resistance according to the value(s) in the table below.

      Standard resistance

      Tester Connection Specified Condition
      20°C (68°F)
      E4-13 (SLU+) - E4-12 (SLU-) 5.0 to 5.6 Ω
    4. Measure the resistance according to the value(s) in the table below.

      Standard resistance (Check for short)

      Tester Connection Specified Condition
      E4-13 (SLU+) - Body ground 10 kΩ or higher
      E4-12 (SLU-) - Body ground

    NG → REPAIR OR REPLACE HARNESS OR CONNECTOR 

    OK → REPLACE ECM 

  3. INSPECT SHIFT SOLENOID VALVE SLU 
    1. Remove the shift solenoid valve SLU.
      Fig 3: Identifying Shift Solenoid Valve SLU
      GTY100118Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
    2. Measure the resistance according to the value(s) in the table below.

      Standard resistance

      Tester Connection Specified Condition
      20°C (68°F)
      1 - 2 5.0 to 5.6 Ω
    3. Connect the positive (+) lead with a 21 W bulb to terminal 2 and the negative (-) lead to terminal 1 of the solenoid valve connector, then check the movement of the valve.

      OK

      The solenoid makes an operating sound.

    NG → REPLACE SHIFT SOLENOID VALVE SLU 

    OK → REPAIR OR REPLACE TRANSMISSION WIRE