DTC C1747/47: Leveling Solenoid Valve Circuit: Description
The suspension control ECU opens the leveling solenoid valve (No. 2 height control valve) to allow compressed air to flow into the height control cylinder (pneumatic cylinder) and raise the vehicle height.
The No. 2 height control valve consists of a leveling solenoid valve and a gate solenoid valve.
The leveling solenoid valve opens and closes the passage between the height control compressor and the height control cylinder (pneumatic cylinder).
| DTC Code | DTC Detection Condition | Trouble Area |
|---|---|---|
| C1747/47 | Either condition is met:
|
|
HINT:
- Once the suspension control ECU stores DTC C1747/47 in memory, vehicle height control is suspended until a normal signal is input to the suspension control ECU from the height control valves. However, control is resumed if the engine switch is turned off and then on (IG) again.
- Malfunction in the leveling solenoid valve:
Height control operation is suspended and the height control indicator does not change by operating the height control switch.