LEMON Manuals: Even more car manuals for everyone
Home >> Lexus >> 2010 >> GS 460 >> Repair and Diagnosis >> Accessories & Equipment >> Gauges & Instrument Panels >> Meter / Gauge (Diagnostics) >> Meter / Gauge System >> Fail-Safe Chart >> Fail-Safe Chart

Fail-Safe Chart

WATER TEMPERATURE GAUGE:

Condition Fail-safe Operation Fail-safe Deactivation Condition
Water temperature data is interrupted for 5 seconds Gauge needle indicates below "C" Water temperature data is received
FUEL SIGNAL (FUEL INJECTION SIGNAL):

Condition Fail-safe Operation Fail-safe Deactivation Condition
While engine switch is in on (IG) position, fuel injection signal is interrupted for 60 seconds Fuel gauge calibration is performed using average fuel consumption data Engine switch is turned from off to on (IG) and normal data is received
FUEL SIGNAL (GAUGE SIGNAL):

Condition Fail-safe Operation Fail-safe Deactivation Condition
While engine switch is in the on (IG) position, sender signal is interrupted for 60 seconds and malfunction signal is received from one of the gauges for 10 to 20 seconds Needle indicates "E", and warning light comes on Engine switch is turned from off to on (IG) and normal data is received
SHIFT INDICATOR:

Condition Fail-safe Operation Fail-safe Deactivation Condition
"P to D" data is interrupted for 3 seconds All indicators go off Normal data is received
"S" data is interrupted for 3 seconds "S" indicator goes off Normal data is received
GEAR POSITION INDICATOR (1 TO 6):

Condition Fail-safe Operation Fail-safe Deactivation Condition
Gear position data is interrupted for 3 seconds or malfunction signal is received Indicator goes off Normal data is received
ABS AND BRAKE:

Condition Fail-safe Operation Fail-safe Deactivation Condition
ABS and brake data is interrupted for 10 seconds Warning light comes on Normal data is received
DOOR:

Condition Fail-safe Operation Fail-safe Deactivation Condition
Regular data is interrupted Data received most recently remains displayed Normal data is received
TAIL:

Condition Fail-safe Operation Fail-safe Deactivation Condition
Regular data is interrupted Data received most recently remains displayed Normal data is received
BEAM:

Condition Fail-safe Operation Fail-safe Deactivation Condition
Regular data is interrupted for 10 seconds or more Indicator goes off Normal data is received
TAIL OR HEAD:

Condition Fail-safe Operation Fail-safe Deactivation Condition
Regular data is interrupted for 10 seconds or more Indicator goes off Normal data is received
FR FOG:

Condition Fail-safe Operation Fail-safe Deactivation Condition
Regular data is interrupted for 10 seconds or more Indicator goes off Normal data is received.
AIRBAG:

Condition Fail-safe Operation Fail-safe Deactivation Condition
Airbag data is interrupted for 10 seconds or there is malfunction in the meter's internal CPU Warning light comes on Normal data is received
OUTSIDE TEMP:

Condition Fail-safe Operation Fail-safe Deactivation Condition
Abnormal data and sensor malfunctioning data are received "--°F" is displayed Normal data is received
Outside temperature. data is interrupted for 10 seconds "E" is displayed Normal data is received
MULTI-INFORMATION:

Condition Fail-safe Operation Fail-safe Deactivation Condition
Cruise information data is interrupted for 60 seconds Display becomes blank (only measurement units are displayed) Normal data is received
LIGHT CONTROL RHEOSTAT:

Condition Fail-safe Operation Fail-safe Deactivation Condition
Rheostat data is interrupted for 10 seconds or abnormal data is received Display remains in daytime mode Normal data is received