Typical Enabling Conditions
WARNING: This page is about a different car, the 2009 Lexus IS 250. However, it is still accessible from the selected car via links, so may be relevant.
| Monitor runs whenever following DTCs are not present | None |
| EVAP key-off monitor runs when all of following conditions are met: | - |
| Atmospheric pressure | 70 to 110 kPa (525 to 825 mmHg) |
| Battery voltage | 10.5 V or more |
| Vehicle speed | Less than 2.5 mph (4 km/h) |
| Engine switch | OFF |
| Time after key off | 5, 7 or 9.5 hours |
| Canister pressure sensor malfunction (P0450, P0452 and P0453) | Not detected |
| Purge VSV | Not operated by scan tool |
| Vent valve | Not operated by scan tool |
| Leak detection pump | Not operated by scan tool |
| Both of the following conditions are met before key off: | Conditions 1 and 2 |
| 1. Duration that vehicle has been driven | 5 minutes or more |
| 2. EVAP purge operation | Performed |
| ECT | 4.4 to 35°C (40 to 95°F) |
| IAT | 4.4 to 35°C (40 to 95°F) |
- Key-off monitor sequence 1 to 8 1. ATMOSPHERIC PRESSURE MEASUREMENT
Next sequence is run if following condition is met: - Atmospheric pressure change Less than 0.3 kPa (2.25 mmHg) for 1 second 2. FIRST REFERENCE PRESSURE MEASUREMENTNext sequence is run if all of the following conditions are met: Conditions 1, 2 and 3 1. EVAP pressure just after reference pressure measurement start -1 kPa (-7.5 mmHg) or less 2. Reference pressure -4.85 to -1.05 kPa (-36.38 to -7.87 mmHg) 3. Reference pressure Saturated within 1 minute 3. EVAP CANISTER VENT VALVE CLOSE STUCK CHECKNext sequence is run if following condition is met: - EVAP pressure change after vent valve is ON 0.3 kPa (2.25 mmHg) or more 4. VACUUM INTRODUCTIONNext sequence is run if the following condition is met: - EVAP pressure 15 minutes or less 5. EVAP CANISTER PURGE VALVE CLOSE STUCK CHECKNext sequence is run if following condition is met: - EVAP pressure change after purge valve is open 0.3 kPa (2.25 mmHg) or more 6. SECOND REFERENCE PRESSURE MEASUREMENTNext sequence is run if all of following conditions are met: Conditions 1, 2, 3 and 4 1. EVAP pressure just after reference pressure measurement start -1 kPa (-7.5 mmHg) or less 2. Reference pressure -4.85 to -1.05 kPa (-36.38 to -7.87 mmHg) 3. Reference pressure Saturated within 1 minute 4. Difference between first reference pressure and second reference pressure Less than 0.7 kPa (5.25 mmHg) 7. LEAK CHECKNext sequence is run if following condition is met: - EVAP pressure when vacuum introduction is complete Less than second reference pressure 8. ATMOSPHERIC PRESSURE MEASUREMENTEVAP monitor is complete if the following condition is met: - Atmospheric pressure difference between sequence 1 and 8 0.3 kPa (2.25 mmHg) or less