Typical Enabling Conditions
WARNING: This page is about a different car, the 2009 Lexus IS 350. However, it is still accessible from the selected car via links, so may be relevant.
| Monitor runs whenever following DTCs not present | None |
| EVAP key-off monitor runs when all of the following conditions are met: | - |
| Atmospheric pressure | 70 to 110 kPa-a (525 to 825 mmHg-a) |
| Battery voltage | 10.5 V or more |
| Vehicle speed | Below 2.5 mph (4 km/h) |
| Engine switch | Off |
| Time after key off | 5 or 7 or 9.5 hours |
| EVAP pressure sensor malfunction (P0450, P0451, P0452 and P0453) | Not detected |
| EVAP canister purge valve | Not operated by scan tool |
| EVAP canister vent valve | Not operated by scan tool |
| EVAP leak detection pump | Not operated by scan tool |
| Both of the following conditions are met before key off: | Conditions 1 and 2 |
| 1. Duration that vehicle has been driven | 5 minutes or more |
| 2. EVAP purge operation | Performed |
| ECT | 4.4 to 35°C (40 to 95°F) |
| IAT | 4.4 to 35°C (40 to 95°F) |
- Key-off monitor sequence 1 to 8 1. ATMOSPHERIC PRESSURE MEASUREMENT
Next sequence is run if the following condition is met: - Atmospheric pressure change Less than 0.3 kPa (2.25 mmHg) for 1 second 2. FIRST REFERENCE PRESSURE MEASUREMENTNext sequence is run if all of the following conditions are met: Conditions 1, 2 and 3 1. EVAP pressure just after reference pressure -1 kPa (-7.5 mmHg) or less 2. Reference pressure -4.85 to -1.057 kPa (-36.4 to -7.93 mmHg) 3. Reference pressure Saturated within 60 seconds 3. EVAP CANISTER VENT VALVE CLOSE STUCK CHECKNext sequence is run if the following condition is met: - EVAP pressure change after vent valve is ON 0.3 kPa (2.25 mmHg) or more 4. VACUUM INTRODUCTIONNext sequence is run if the following condition is met: - EVAP pressure Saturated within 15 minutes 5. EVAP CANISTER PURGE VALVE CLOSE STUCK CHECKNext sequence is run if following condition is met: - EVAP pressure change after purge valve is open 0.3 kPa (2.25 mmHg) or more 6. SECOND REFERENCE PRESSURE MEASUREMENTNext sequence is run if all of the following conditions are met: Conditions 1, 2, 3 and 4 1. EVAP pressure just after reference pressure -1 kPa (-7.5 mmHg) or less 2. Reference pressure -4.85 to -1.057 kPa (-36.4 to -7.93 mmHg) 3. Reference pressure Saturated within 60 seconds 4. Difference between first reference pressure and second reference pressure Less than 0.7 kPa (5.25 mmHg) 7. LEAK CHECKNext sequence is run if the following condition is met: - EVAP pressure when vacuum introduction complete Second reference pressure or less 8. ATMOSPHERIC PRESSURE MEASUREMENTEVAP monitor is complete if the following condition met: - Atmospheric pressure difference between sequence 1 and 8 Within 0.3 kPa (2.25 mmHg)