DTC C1799/99: Access Mode Switch Circuit: Procedure
- READ VALUE USING TECHSTREAM
- Connect the Techstream to the DLC3.
- Turn the ignition switch to the ON position, and push the Techstream main switch on.
- Select the item below in the DATA LIST, and read its value displayed on the Techstream.
Air suspension
Item Normal Condition Access Mode Switch ON: Access mode switch pressing
OFF: - - Check that the value displayed on the Techstream changes by pressing the access mode switch.
OK
Access mode switch value changes.
NG → Go to next step
OK → REPLACE SUSPENSION CONTROL ECU
- INSPECT ACCESS MODE SWITCH
- Disconnect the access mode switch connector.
- Measure the resistance according to the values in the table below.
Standard resistance
Switch Condition Tester Connection Specified Condition Pushed in 3 (LMSW) - 4 (GND) Below 1 Ω Free 3 (LMSW) - 4 (GND) 10 kΩ or higher
NG → REPLACE ACCESS MODE SWITCH
OK: Go to next step
- CHECK HARNESS AND CONNECTOR (SUSPENSION CONTROL ECU - ACCESS MODE SWITCH)
- Disconnect the suspension control ECU S16 connector.
- Measure the resistance according to the values in the table below.
Standard resistance
Tester Connection Specified Condition S16-3 (LMSW) - A13-3 (LMSW) Below 1 Ω S16-3 (LMSW) - Body ground 10 kΩ or higher
NG → REPAIR OR REPLACE HARNESS OR CONNECTOR
OK: Go to next step
- CHECK HARNESS AND CONNECTOR (ACCESS MODE SWITCH - BODY GROUND)
- Measure the resistance according to the values in the table below.
Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
Standard resistance
Tester Connection Specified Condition A13-4 (GND) - Body ground Below 1 Ω
NG → REPAIR OR REPLACE HARNESS OR CONNECTOR
OK → REPLACE SUSPENSION CONTROL ECU
- Measure the resistance according to the values in the table below.