LEMON Manuals: Even more car manuals for everyone
Home >> Lexus >> 2009 >> LS 600hL >> Repair and Diagnosis >> Hybrid/Electric Powertrain >> Testing and Diagnosis >> Hybrid Vehicle Control (Diagnostic Codes (P1606-308 - U0424-537) & Circuit Tests) >> Hybrid Control System >> DTC P3233-750: Short to B+ in Blocking of HV Gate Connection >> Procedure

DTC P3233-750: Short to B+ in Blocking of HV Gate Connection: Procedure

  1. CHECK HARNESS AND CONNECTOR (HYBRID VEHICLE CONTROL ECU-INVERTER WITH CONVERTER ASSEMBLY) 
    WARNING:

    Be sure to wear insulated gloves.

    1. Turn the power switch off.
    2. Remove the service plug grip. Refer to PRECAUTION .
      NOTE:

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair information because this may cause a malfunction.

    3. Disconnect connector A76 from the hybrid vehicle control ECU.
    4. Disconnect the low voltage connector from the inverter with converter assembly.
      Fig 1: Checking Harness And Connector (Hybrid Vehicle Control ECU-Inverter With Converter Assembly)
      GTY148382Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
    5. Turn the power switch on (IG).
    6. Measure the voltage according to the value(s) in the table below.
      Fig 2: Checking Harness And Connector (Hybrid Vehicle Control ECU-Inverter With Converter Assembly)
      GTY147804Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002

      Standard voltage

      Tester Connection Switch Condition Specified Condition
      A76-25 (HSDN) - Body ground Power switch on (IG) Below 1 V
      NOTE:

      Turning the power switch on (IG) with the connector of the hybrid vehicle control ECU or the low voltage connector of the inverter with converter assembly disconnected causes other DTCs to be stored. Clear the DTCs after performing this inspection.

    7. Turn the power switch off.
    8. Measure the resistance according to the value(s) in the table below.

      Standard resistance

      Tester Connection Switch Condition Specified Condition
      A76-25 (HSDN) - A77-25 (HSDN) Power switch off Below 1 Ω

    NG → REPAIR OR REPLACE HARNESS OR CONNECTOR 

    OK: Go to next step 

  2. CHECK INVERTER WITH CONVERTER ASSEMBLY 
    WARNING:

    Be sure to wear insulated gloves.

    1. Check that the service plug grip is not installed.
    2. Measure the resistance according to the value(s) in the table below.
      Fig 3: A77 Connector
      GTY137755Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002

      Standard resistance

      Tester Connection Switch Condition Specified Condition
      A77-25 (HSDN) - A77-10 (+B) Power switch off 3.5 kΩ or higher
      A77-25 (HSDN) - A77-11 (+B2) Power switch off 3.5 kΩ or higher
      A77-25 (HSDN) - A77-30 (GND1) Power switch off 2.65 to 3.55 kΩ

    NG → See step   4 

    OK → See step   3 

  3. REPLACE HYBRID VEHICLE CONTROL ECU. Refer to  REMOVAL 
  4. REPLACE INVERTER WITH CONVERTER ASSEMBLY. Refer to  REMOVAL