DTC P2798-858: Auxiliary Transmission Fluid Pump Control Circuit Low: Procedure
- CHECK HYBRID VEHICLE CONTROL ECU (CHECK WAVEFORM)
- Connect an oscilloscope between the hybrid vehicle control ECU terminals specified in the table below, and measure the waveform.
Item Contents Terminal A74-33 (OPST) - A75-7(E1) Equipment Setting 5 V/DIV., 5 ms./DIV. Condition Power switch on (IG) Result
Result Proceed to Waveform is flat, and is stuck on the GND side. A Normal B
B → See step 7
A: Go to next step
- Connect an oscilloscope between the hybrid vehicle control ECU terminals specified in the table below, and measure the waveform.
- CHECK CONNECTOR CONNECTION CONDITION (OIL PUMP MOTOR CONTROLLER CONNECTOR) NOTE:
Before disconnecting the connectors, confirm that they are properly connected by checking that the locking claws are engaged and that the connectors do not pull out.
- Check the connections of the oil pump motor controller connectors.
OK
The connectors are connected securely and there are no contact problems.
HINT:
For connector A, when connecting it, insert it with the locking lever in the raised position. Rotate the lever downward and make sure that the connector is pulled into its socket. When the locking lever is in its fully closed position, a click will be heard as its locking claws engage. After the click is heard, pull up on the connector to confirm that it is properly connected.
NG → CONNECT SECURELY
OK: Go to next step
- Check the connections of the oil pump motor controller connectors.
- CHECK CONNECTOR CONNECTION CONDITION (HYBRID VEHICLE CONTROL ECU CONNECTOR)
- Check the connections of the hybrid vehicle control ECU connectors.
Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
OK
The connectors are connected securely and there are no contact problems.
NG → CONNECT SECURELY
OK: Go to next step
- Check the connections of the hybrid vehicle control ECU connectors.
- CHECK HYBRID VEHICLE CONTROL ECU (VOLTAGE)
- Turn the power switch off.
- Disconnect connector A78 from the oil pump motor controller.
- Turn the power switch on (IG).
- Measure the voltage according to the value(s) in the table below.
Standard voltage
Tester Connection Switch Condition Specified Condition A78-7 (OPST) - Body ground Power switch on (IG) 7 to 12 V NOTE:Turning the power switch on (IG) with the oil pump motor controller connector disconnected causes other DTCs to be stored. Clear the DTCs after performing this inspection.
NG → See step 6
OK: Go to next step
- CHECK OIL PUMP MOTOR CONTROLLER
- Turn the power switch off.
- Measure the resistance according to the value(s) in the table below.
Standard resistance
Tester Connection Switch Condition Specified Condition A78-7 (OPST) - Body ground Power switch off 10 kΩ or higher
NG → See step 9
OK → See step 8
- CHECK HARNESS AND CONNECTOR
- Turn the power switch off.
- Disconnect connector A74 from the hybrid vehicle control ECU.
- Measure the resistance according to the value(s) in the table below.
Standard resistance
Tester Connection Switch Condition Specified Condition A74-33 (OPST) - Body ground and other terminals Power switch off 10 kΩ or higher
NG → REPAIR OR REPLACE HARNESS OR CONNECTOR
OK → See step 8
- CHECK FOR INTERMITTENT PROBLEMS
- Check for intermittent problems. Refer to CHECK FOR INTERMITTENT PROBLEMS .
NG → REPAIR OR REPLACE MALFUNCTIONING PARTS, COMPONENT AND AREA
OK → See step 9
- REPLACE HYBRID VEHICLE CONTROL ECU. Refer to REMOVAL
- REPLACE OIL PUMP MOTOR CONTROLLER. Refer to REMOVAL