DTC P0A94-550: DC / DC Converter Performance: Procedure
- CHECK CONNECTOR CONNECTION CONDITION (INVERTER WITH CONVERTER ASSEMBLY CONNECTOR) NOTE:
Before disconnecting the connector, confirm that it is properly connected by checking that the locking claws are engaged and that the connector does not pull out.
- Check the connection of the low voltage connector of the inverter with converter assembly.
Result
The connectors are connected securely and there are no contact problems.
HINT:
When connecting the connector, insert it with the locking lever in the raised position. Rotate the lever downward and make sure that the connector is pulled into its socket. When the locking lever is in its fully closed position, a click will be heard as its locking claws engage. After the click is heard, pull up on the connector to confirm that it is properly connected.
NG → CONNECT SECURELY
OK → See step 2
- Check the connection of the low voltage connector of the inverter with converter assembly.
- REPLACE INVERTER WITH CONVERTER ASSEMBLY. Refer to REMOVAL