Continuity And Resistance Check

  1. Disconnect the battery terminal or wire so there is no voltage between the check points.
  2. Contact the two leads of an ohmmeter to each of the check points.
    Fig 1: Checking Switch Continuity
    G07595267Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002

    If the circuit has diodes, reverse the two leads and check again.

    When contacting the negative lead to the diode positive side and the positive lead to the negative side, there should be continuity.

    When contacting the two leads in reverse, there should be no continuity.

    Fig 2: Checking Diode Continuity
    G07595268Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
  3. Use a volt/ohmmeter with high impedance (10 kΩ/V minimum) for troubleshooting of the electrical circuit.
    Fig 3: Identifying Digital And Analog Type Volt/Ohmmeters
    G07595269Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002