Light Control Rheostat: Inspection: Inspection
- INSPECT LIGHT CONTROL RHEOSTAT
- Measure the voltage according to the value(s) in the table below.
Standard voltage
Tester Connection Condition Specified condition 1 (T) - Body ground Ignition switch ON, Taillight switch OFF → ON Below 1 V → 10 to 14 V 2 (IG) - Body ground Ignition switch OFF → ON Below 1 V → 10 to 14 V - Measure the resistance according to the value(s) in the table below.
Standard resistance
Tester Connection Condition Specified condition 5 (E) - Body ground Always Below 1 Ω - Check the resistance between terminal 4 (RV) and terminal 3 (T) when operating the light control rheostat volume knob. Also, check that the resistance changes continuously.
Standard resistance
Turn the knob to maximum
Approx. 10 kΩ
Turn the knob to minimum
Approx. 0 kΩ
- Measure the voltage according to the value(s) in the table below.