Operating Light Control Rheostat Does Not Change Light Brightness: Procedure
- CHECK MULTIPLEX COMMUNICATION SYSTEM
- Check the DTC . Refer to DTC CHECK / CLEAR
.RESULT:
Result Proceed to DTC is not output A DTC is output B
B → See step 3
A: Go to next step
- Check the DTC . Refer to DTC CHECK / CLEAR
.
- READ VALUE USING TECHSTREAM (RHEOSTAT UP SWITCH, RHEOSTAT DOWN SWITCH)
- Connect the Techstream to the DLC3.
- Power switch on (IG).
- Turn the tester ON.
- Enter following menus: Body Electrical / D-SEAT SW / Data List.
- Check the values by referring to the table below.D-SEAT SW:
Tester Display Measurement Item/Range Normal Condition Diagnostic Note Rheostat Up SW Rheostat up switch condition ON: Rheostat up switch is pushed
OFF: Rheostat up switch is not pressed- Rheostat Down SW Rheostat down switch condition ON: Rheostat down switch is pushed
OFF: Rheostat down switch is not pressed- OK
Switch condition (ON/OFF) can be switched by actual operation.
NG → REPLACE INTEGRATION CONTROL AND PANEL
OK → REPLACE COMBINATION METER
- GO TO MULTIPLEX COMMUNICATION SYSTEM. Refer to DIAGNOSTIC TROUBLE CODE CHART