Entire Combination Meter Does Not Operate: Procedure
- CHECK WIRE HARNESS (COMBINATION METER - BATTERY AND BODY GROUND)
- Disconnect the K31 meter connector.
- Measure the resistance and voltage of the wire harness side connector.
Standard resistance
Standard voltage
Tester Connection Specified Condition K31-20 (ES) - Body ground Below 1 Ω Tester Connection Condition Specified Condition K31-1 (IG+) - Body ground Power switch ON (IG) 10 to 14 V K31-21 (B) - Body ground Always 10 to 14 V K31-22 (B) - Body ground Always 10 to 14 V
NG → REPAIR OR REPLACE HARNESS OR CONNECTOR
OK: Go to next step
- CHECK COMBINATION METER (AUTOMATIC LIGHT CONTROL SENSOR SYSTEM)
- Disconnect the K31 meter connector.
- Measure the resistance of the wire harness side connector.
Standard resistance
Tester Connection Specified Condition K31-36 (MS5) - Body ground 10 kΩ or higher
OK → REPLACE COMBINATION METER
NG: Go to next step
- CHECK WIRE HARNESS (AUTOMATIC LIGHT CONTROL SENSOR - COMBINATION METER)
- Disconnect the V34 sensor connector.
- Disconnect the K31 meter connector.
- Measure the resistance of the wire harness side connector.
Standard resistance
Tester Connection Specified Condition K31-16 (MS5) - K31-18 (MSG) 10 kΩ or higher
NG → REPAIR OR REPLACE HARNESS OR CONNECTOR
OK → REPLACE AUTOMATIC LIGHT CONTROL SENSOR