Odo/TRIP SWITCH MALFUNCTION: Procedure
- CHECK MULTIPLEX COMMUNICATION SYSTEM
Please follow the information. Refer to HOW TO PROCEED WITH TROUBLESHOOTING .
If the multiplex communication system is operating normally, proceed to the next step.
Next: Go to next step
- READ VALUE USING TECHSTREAM (ODO/TRIP CHANGE SW, TRIP RESET SW)
- Connect the Techstream to the DLC3.
- Ignition switch on (IG).
- Turn the tester ON.
- Enter following menus: Body Electrical / D-SEAT SW / Data List.
- Check the values by referring to the table below.D-SEAT SW:
Tester Display Measurement Item/Range Normal Condition Diagnostic Note ODO/TRIP Change SW ODO/TRIP change switch condition ON: ODO/TRIP change switch is pushed
OFF: ODO/TRIP change switch is not pressed- Trip Reset Sw Trip Reset switch condition ON: ODO/TRIP change switch is pushed
OFF: ODO/TRIP change switch is not pressed- OK
Switch condition (ON/OFF) can be switched by actual operation.
NG → REPLACE INTEGRATION CONTROL AND PANEL ASSEMBLY
OK → REPLACE COMBINATION METER