Operating Light Control Rheostat does not Change Light Brightness: Procedure
- SYSTEM CHECK
- Turn the engine switch on (IG).
- Turn the light control rheostat knob fully upwards.
- Turn the light control rheostat knob fully downwards.
- Turn the light control rheostat knob fully upwards and light control switch is on TAIL or HEAD.
- Check the meter illumination.
Result
Result Proceed to Meter illumination does not change when operating the light control rheostat knob A Dimmer cancel does not operate (Meter illumination does not dim). B
B → See step 3
A: Go to next step
- READ VALUE USING TECHSTREAM (RHEOSTAT)
- Connect Techstream to the DLC3.
- Turn the engine switch on (IG).
- Turn the tester ON.
- Enter the following menus: Body Electrical / Combination Meter / Active Test.
- Check the values by referring to the table below.COMBINATION METER:
Tester Display Measurement Item/Range Normal Condition Diagnostic Note Rheostat value Light control rheostat/Min.: 0%, Max.: 100% Light control rheostat switch is Dark (0%) → Bright (100%) - OK
The value displayed on the tester gradually changes as the actual rheostat operation.
NG → See step 4
OK: Go to next step
- READ VALUE USING TECHSTREAM (TAIL CANCEL SW)
- Connect the Techstream to the DLC3.
- Turn the engine switch on (IG).
- Turn the tester ON.
- Enter the following menus: Body Electrical / Combination Meter / Data List.
- Check the values by referring to the table below.COMBINATION METER:
Tester Display Measurement Item/Range Normal Condition Diagnostic Note Tail Cancel SW Tail cancel switch is OFF/ON OFF: Light control rheostat position is except below - ON: Turn the Light control rheostat knob fully upwards - OK
Condition displayed on the tester is the same as the actual rheostat position.
NG → See step 6
OK → REPLACE COMBINATION METER ASSEMBLY
- INSPECT LIGHT CONTROL RHEOSTAT
- Remove the light control rheostat.
- Measure the resistance according to the value(s) in the table below.
Standard resistance
Tester Connection Condition Specified Condition E55-3 (T) - E55-4 (RV) Turn the rheostat knob fully upwards 8 kΩ or higher E55-3 (T) - E55-4 (RV) Rheostat knob is between MIN. and MAX. The value changes gradually
(Between below 1 to 8 kΩ)E55-3 (T) - E55-4 (RV) Turn the rheostat knob fully downwards Below 1 Ω
NG → REPLACE LIGHT CONTROL RHEOSTAT
OK: Go to next step
- CHECK HARNESS AND CONNECTOR (COMBINATION METER - LIGHT CONTROL RHEOSTAT)
- Disconnect the E19 and E55 connectors.
- Measure the resistance according to the value(s) in the table below.
Standard resistance
Tester Connection Condition Specified Condition E19-6 (TR) - E55-4 (RV) Always Below 1 Ω E19-10 (E3) - E55-3 (T) Always Below 1 Ω E19-16 (TC) - E55-1 (TC) Always Below 1 Ω E55-1 (TC) - Body ground Always 10 kΩ or higher E55-3 (T) - Body ground Always 10 kΩ or higher E55-4 (RV) - Body ground Always 10 kΩ or higher
NG → REPAIR OR REPLACE HARNESS OR CONNECTOR
OK → REPLACE COMBINATION METER ASSEMBLY
- INSPECT LIGHT CONTROL RHEOSTAT
- Remove the light control rheostat with connector still connected.
- Measure the resistance according to the value(s) in the table below.
Standard resistance
Tester Connection Condition Specified Condition E55-1 (TC) - E55-3 (T) Turn the rheostat knob fully downwards Below 1 Ω E55-1 (TC) - E55-3 (T) Turn the rheostat knob fully upwards 8 kΩ or higher
NG → REPLACE LIGHT CONTROL RHEOSTAT
OK: Go to next step
- CHECK HARNESS AND CONNECTOR (COMBINATION METER - LIGHT CONTROL RHEOSTAT)
- Disconnect the E19 and E55 connectors.
- Measure the resistance according to the value(s) in the table below.
Standard resistance
Tester Connection Condition Specified Condition E55-1 (TC) - E19-16 (TC) Always Below 1 Ω E55-1 (TC) - Body ground Always 10 kΩ or higher
NG → REPAIR OR REPLACE HARNESS OR CONNECTOR
OK → REPLACE COMBINATION METER ASSEMBLY