TYPICAL MALFUNCTION THRESHOLDS
| One of the following conditions A, B and C is met | - |
| A. All of the following conditions (a), (b) and (c) are met | - |
| (a) Battery voltage | 11 V or more, and less than 13 V |
| (b) Target duty ratio | Less than 70% |
| (c) Output signal duty ratio | 100% or more |
| B. All of the following conditions (a), (b) and (c) are met | - |
| (a) Battery voltage | 13 V or more |
| (b) Target duty ratio | Less than 80% |
| (c) Output signal duty ratio | 100% or more |
| C. Both of the following conditions (a) and (b) are met | - |
| (a) Current cut status | Not cut |
| (b) Output signal duty ratio | 3% or less |