Inspection Procedure
WARNING: This page is about a different car, the 2006 Lexus RX 400h. However, it is still accessible from the selected car via links, so may be relevant.
- CHECK HARNESS AND CONNECTOR (HV CONTROL ECU - IGCT RELAY)
- Disconnect the H34 connector from the HV control ECU.
- Remove the IGCT relay from the R/B No. 2.
- Measure the voltage according to the value(s) in the table below when the ignition switch is in the ON position.NOTE: Turning the ignition switch to the ON position with the HV control ECU connectors disconnected causes other DTCs to be stored. Clear the DTCs after performing the inspection.
Standard voltage
HV CONTROL ECU - IGCT RELAYTester Connection Specified Condition MREL (H34-12) - Body ground Below 1 V
NG: REPAIR OR REPLACE HARNESS OR CONNECTOR
OK: GO TO NEXT STEP
- INSPECT IGCT RELAY
- Remove the IGCT relay from the engine room R/B No. 2.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
IGCT RELAYTester Connection Specified Condition 3 - 5 10 kΩ or more 3 - 5 Below 1 Ω
(when battery voltage is applied to terminals 1 and 2)
NG: REPLACE IGCT RELAY
OK: REPLACE HYBRID VEHICLE CONTROL ECU