LEMON Manuals: Even more car manuals for everyone
Home >> Lexus >> 2008 >> RX 400h AWD >> Repair and Diagnosis >> External Pages >> Different car >> Section 158 (Hybrid Vehicle Control (P310) - RX400H - DTC P0336-137 Through P0A32-666) >> DTC P0A1D-139 Hybrid Powertrain Control Module >> Inspection Procedure

Inspection Procedure

WARNING: This page is about a different car, the 2006 Lexus RX 400h. However, it is still accessible from the selected car via links, so may be relevant.
  1. CHECK HARNESS AND CONNECTOR (HV CONTROL ECU - IGCT RELAY) 
    1. Disconnect the H34 connector from the HV control ECU.
    2. Remove the IGCT relay from the R/B No. 2.
    3. Measure the voltage according to the value(s) in the table below when the ignition switch is in the ON position.
      NOTE: Turning the ignition switch to the ON position with the HV control ECU connectors disconnected causes other DTCs to be stored. Clear the DTCs after performing the inspection.

      Standard voltage 

      HV CONTROL ECU - IGCT RELAY

      Tester Connection Specified Condition
      MREL (H34-12) - Body ground Below 1 V
      Fig 1: Checking Harness And Connector (HV Control ECU - IGCT Relay)
      G04111958Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002

    NG: REPAIR OR REPLACE HARNESS OR CONNECTOR 

    OK: GO TO NEXT STEP 

  2. INSPECT IGCT RELAY 
    1. Remove the IGCT relay from the engine room R/B No. 2.
    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance 

      IGCT RELAY

      Tester Connection Specified Condition
      3 - 5 10 kΩ or more
      3 - 5 Below 1 Ω
      (when battery voltage is applied to terminals 1 and 2)
      Fig 2: Inspecting IGCT Relay
      G04111959Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002

    NG: REPLACE IGCT RELAY 

    OK: REPLACE HYBRID VEHICLE CONTROL ECU